Vertiv GXE3-1000IRT2UXL

Uporabniški priročnik za UPS Vertiv Liebert GXE3-1000IRT2UXL

Model: GXE3-1000IRT2UXL

1. Uvod

The Vertiv Liebert GXE UPS is an in-line dual conversion single-phase inverter designed to provide robust power protection for critical IT equipment. This system ensures continuous and reliable power, safeguarding connected devices from various AC sector disruptions through its advanced inline double conversion technology. Its flexible design allows for both rack-mount and tower configurations, making it suitable for diverse application environments.

2. Varnostne informacije

Please read and understand all safety instructions before installing, operating, or maintaining the UPS. Failure to follow these instructions may result in electric shock, fire, or serious injury.

3. Izdelek je končanview

3.1 Ključne lastnosti

3.2 Visual Guide

Spredaj view of the Vertiv Liebert GXE3-1000IRT2UXL UPS in tower configuration, showing the LCD display and control buttons.
Slika 3.2.1: Spredaj View of the UPS. This image displays the front panel of the UPS, highlighting the LCD screen and user interface buttons for status monitoring and configuration.
Zadaj view of the Vertiv Liebert GXE3-1000IRT2UXL UPS, showing input power, circuit breaker, and eight IEC C13 output receptacles.
Slika 3.2.2: Zadaj View of the UPS. This image shows the back panel, detailing the power input, circuit breaker, and eight IEC C13 output ports for connecting protected devices.
Tri četrtine view of the Vertiv Liebert GXE3-1000IRT2UXL UPS in tower configuration with base stands.
Figure 3.2.3: UPS in Tower Configuration. This perspective view illustrates the UPS standing upright with its included base stands, suitable for tower deployment.
Stran view of the Vertiv Liebert GXE3-1000IRT2UXL UPS in tower configuration, showing the ventilation grilles.
Slika 3.2.4: stran View of the UPS. This image provides a side profile, highlighting the ventilation grilles essential for proper heat dissipation.

4. Nastavitev

4.1 Razpakiranje in pregled

Carefully unpack the UPS and its accessories. Inspect for any shipping damage. Retain the packaging for future use or return.

4.2 Namestitev

Place the UPS in a well-ventilated area, away from direct sunlight, heat sources, and excessive dust or moisture. Ensure sufficient clearance around the unit for proper airflow.

4.3 Configuration (Tower/Rack-Mount)

The GXE3-1000IRT2UXL can be deployed as a tower unit using the included stands or installed in a standard 19-inch rack using an optional rack-mount kit (sold separately). Follow the instructions provided with the rack-mount kit for rack installation.

4.4 Električne povezave

  1. Vhodna moč: Connect the UPS input power cord to a grounded electrical outlet. Ensure the outlet provides the correct voltage (230V) and current capacity.
  2. Izhodne naprave: Connect your critical IT equipment (servers, networking devices, etc.) to the IEC C13 output receptacles on the rear of the UPS. Do not overload the UPS beyond its rated capacity (900W).
  3. Komunikacijska vrata: For monitoring and management, connect the appropriate communication cables (USB, RS-232, or optional network card) to your computer or network.

4.5 Začetni vklop

After all connections are secure, press the power button on the front panel to turn on the UPS. The LCD display will illuminate, and the UPS will perform a self-test. Allow the batteries to charge for at least 4 hours before connecting critical loads for optimal runtime.

5. Upravljanje UPS-a

5.1 LCD-zaslon in upravljanje

The user-friendly LCD display provides real-time status information, including input/output voltage, load level, battery capacity, and operational mode. Use the navigation buttons next to the LCD to scroll through menus and configure settings.

5.2 Načini delovanja

5.3 Upravljanje programske opreme

For enhanced monitoring and management, install the Vertiv Power Assist software on a connected computer for local control and graceful shutdown. For network-wide management, utilize Vertiv Power Insight or an optional Vertiv Liebert Intellislot IS-UNITY Network Management Card.

6. Vzdrževanje

6.1 Zamenjava baterije

The Vertiv Liebert GXE3-1000IRT2UXL features hot-swappable internal batteries, allowing for replacement without powering down connected equipment. Refer to the detailed battery replacement guide available on the Vertiv support website for specific instructions. Always use genuine Vertiv replacement batteries.

6.2 Čiščenje

Periodically clean the exterior of the UPS with a soft, dry cloth. Ensure ventilation openings are free from dust and debris to maintain proper airflow and prevent overheating.

6.3 Redni pregledi

Regularly check the UPS status via the LCD display or management software. Verify that input and output connections are secure and that the UPS is operating in the desired mode.

7. Odpravljanje težav

This section provides solutions to common issues you may encounter with your UPS. For more complex problems, contact Vertiv technical support.

TežavaMožen vzrokrešitev
UPS se ne vklopi.No input power; UPS circuit breaker tripped; Battery deeply discharged.Check power cord connection and wall outlet. Reset the circuit breaker. Allow UPS to charge for several hours.
UPS neprekinjeno piska.Overload condition; Low battery.Reduce connected load. Allow batteries to recharge.
UPS se pogosto preklopi v način delovanja z baterijo.Nestabilno napajanje iz omrežja; Previsoka nastavitev občutljivosti.Check utility power quality. Adjust UPS input sensitivity via LCD or software.

8. Specifikacije

AtributVrednost
Številka modelaGXE3-1000IRT2UXL
Zmogljivost (VA/W)1000 VA / 900 W
Vhodna voltage230 V
Faktor izhodne moči0.9
Faktor oblike2U Tower / Rack-Mount Convertible
Izhodne posode8 x IEC60320 C13
tehnologijaDual Conversion Online
Efficiency (Online Mode)do 91 %
Efficiency (ECO Mode)do 96 %
Čas polnjenja< 4 hours to 90% (internal batteries)
Dimenzije (paket)17.24 x 16.93 x 3.39 palcev
Teža predmeta35.2 funtov
ASINB0DX6YTYFZ
UPC767041034967, 767041034394

9. Garancija in podpora

The Vertiv Liebert GXE3-1000IRT2UXL UPS comes with a standard manufacturer's warranty. Please refer to the warranty card included with your product or visit the official Vertiv webza podrobne garancijske pogoje.

Tehnična podpora

For technical assistance, troubleshooting, or service inquiries, please contact Vertiv customer support. Contact information and support resources can be found on the official Vertiv webspletno mesto: www.vertiv.com/en-us/support/

Povezani dokumenti - GXE3-1000IRT2UXL

Prejview Vertiv Liebert GXE UPS 1-3kVA Installer/User Guide - Installation and Operation
Comprehensive installer and user guide for the Vertiv Liebert GXE UPS 1-3kVA series, covering installation, operation, maintenance, troubleshooting, and specifications for reliable power protection.
Prejview Vertiv Liebert GXE UPS: High Performance Power Protection
Explore the Vertiv Liebert GXE, an essential and affordable online double-conversion UPS system offering robust power protection for 6000 VA to 10000 VA applications. Features include high efficiency, flexible rack/tower mounting, scalable runtime, and advanced management.
Prejview Vertiv Liebert GXT5 UPS: Inteligentna in učinkovita zaščita napajanja | Izdelek na vrhuview
Raziščite serijo UPS-jev Vertiv Liebert GXT5, ki ponuja inteligentno in učinkovito zaščito napajanja za kritične aplikacije.view podrobno opisuje njegove lastnosti, specifikacije, družinoview, service packages, accessories, and mounting options, highlighting its compact design, high efficiency, and advanced management capabilities.
Prejview Vertiv Liebert HPM: Visokozmogljive rešitve za hlajenje podatkovnih centrov (4–30 kW)
Raziščite serijo Vertiv Liebert HPM, ki ponuja učinkovite in zanesljive rešitve za klimatizacijo podatkovnih centrov in kritičnih okolij. Odkrijte tehnične specifikacije, ključne lastnosti in načine uporabe za hladilne zmogljivosti od 4 do 30 kW.
Prejview Liebert NXL UPS Installation Manual: 250-400kVA, 60Hz
This installation manual provides comprehensive instructions for the setup and installation of the Liebert NXL UPS, covering single-module and multi-module units ranging from 250-400kVA at 60Hz. It details safety precautions, mechanical and electrical installation procedures, environmental considerations, and system composition.
Prejview Opombe ob izdaji vdelane programske opreme za kartico Liebert IntelliSlot Unity v7.8.0.0
Opombe ob izdaji vdelane programske opreme za kartico Liebert IntelliSlot Unity različice 7.8.0.0, ki podrobno opisujejo združljivost, nove funkcije, varnostne posodobitve in znane težave.