1. Izdelek je končanview
The Elitech RCW-800W-TDE-V2 is a digital temperature data logger designed for remote, real-time temperature monitoring. It supports both 5G and 2.4G WiFi networks, offering stable connectivity for continuous data upload and alert notifications. Equipped with dual external temperature probes, it provides accurate measurements and cloud data storage capabilities. Users can receive SMS, email, app, and web alarms for timely intervention.

Figure 1: Elitech RCW-800W-TDE-V2 Digital Temperature Data Logger.
2. Ključne značilnosti
- Stabilna omrežna povezava: Supports both 5G and 2.4G WiFi, ensuring reliable remote real-time temperature monitoring.
- High Precision Probes: Accurately senses small changes in temperature. Measurement range: -40℉ ~ 176℉ (-40℃ ~ 80℃).
- Nastavljivi parametri: Allows configuration of temperature unit (℃/℉), record interval, upload interval, and alarm interval.
- Zvočni in vizualni alarm: Provides immediate alerts for abnormal temperature conditions.
- Vgrajena polnilna litijeva baterija: Ensures real-time data upload for an extended period (no less than 7 days at 25℃ with 5-minute upload interval) even during power outages.
- Enostavna namestitev: Features a built-in magnet for direct attachment to metallic surfaces like refrigerators, or can be fixed using screws.
- Shranjevanje podatkov v oblaku: Stores data remotely, accessible via mobile app and cloud platform from anywhere.
- Multiple Alert Methods: Receive real-time alerts via LCD screen, SMS, email, and app notifications.
- Offline Data Backup: In case of network interruption, the device can record up to 20,000 offline data points, which will automatically upload once network connection is restored.

Figure 2: Local and Cloud Alarm Capabilities.

Figure 3: Real-time Data Upload and Remote Access.
3. Kaj je v škatli
Ko odprete paket, bi morali najti naslednje elemente:
- Elitech RCW-800W-TDE-V2 Data Logger
- Certifikat o kalibraciji
- Uporabniški priročnik
- AA Batteries (1 included)
4. Navodila za namestitev
Follow these steps to set up your Elitech RCW-800W-TDE-V2 data logger:
- Namestite aplikacijo: Download and install the "Elitech iCold" app on your mobile device. You can scan the QR code below or visit the provided link:

Figure 4: App Download and Initial Setup Steps.
Povezava za prenos: http://www.e-elitech.cn/commonAction.do?method=andrioddl
- Account Registration and Login: Open the Elitech iCold app and register a new account if you don't have one, then log in.
- Vklopite napravo: Ensure the data logger has batteries installed or is connected to a power source.
- Bluetooth Distribution Network: In the app, select to add a new device. The app will guide you to enable Bluetooth on your phone and press the reset button on the data logger to enter configuration mode. The Bluetooth symbol will display on the device screen.
- Povežite se z WiFi: Follow the in-app instructions to connect the data logger to your 5G or 2.4G WiFi network. Enter your WiFi password when prompted.
- Install Probes: Connect the dual external temperature probes to the designated ports on the data logger.
- Namestite napravo: The data logger features a magnetic back for easy attachment to metal surfaces. Alternatively, it can be fixed to a wall using screws.

Figure 5: Magnetic Back for Convenient Mounting.
5. Navodila za uporabo
Once set up, the data logger will begin monitoring and uploading data. Here's how to interact with the device and its data:
5.1 Upravljanje naprave

Figure 6: Device Buttons and Components.
- Home Key (1): Navigates to the main display.
- Celsius or Fahrenheit Switch (2): Toggles the temperature display unit between Celsius (℃) and Fahrenheit (℉).
- Monitoring Start or Stop (3): Initiates or pauses data logging.
- Buzzer On or Off (4): Vklopi ali izklopi zvočni alarm.
- Reset button (5): Used for device reset, often during initial setup or troubleshooting.
- Stikalo za vklop (6): Vklopi ali izklopi napravo.
- Temp Sensor 5M * 2 (7): Ports for connecting the dual 5-meter temperature probes.
5.2 Real-time Data Monitoring
Podatki so lahko viewed in real-time through the Elitech iCold mobile app or the web-based cloud platform. The platform allows you to:
- View current temperature readings from both probes.
- Access historical data charts and graphs.
- Set and modify alarm thresholds and notification preferences.
- Export data for analysis.
Video 1: Elitech Real Time Temperature Monitor in action, demonstrating connectivity and data viewing in various environments like greenhouses, shipping, and laboratories.
6. Vzdrževanje
To ensure optimal performance and longevity of your Elitech data logger, consider the following maintenance tips:
- Čiščenje: Regularly wipe the device and probes with a soft, dry cloth. Avoid using abrasive cleaners or solvents.
- Upravljanje baterije: The built-in lithium battery is rechargeable. Ensure it is charged periodically, especially if the device is used in areas prone to power outages. For continuous operation, keep the device connected to a power source.
- Pregled sonde: Periodically inspect the temperature probes and their cables for any signs of damage or wear. Replace damaged probes to maintain measurement accuracy.
- Posodobitve programske opreme: Check the Elitech iCold app or website for any available firmware or software updates for your device to ensure you have the latest features and bug fixes.
7. Odpravljanje težav
If you encounter issues with your Elitech RCW-800W-TDE-V2, try the following troubleshooting steps:
- Naprava se ne povezuje z omrežjem Wi-Fi:
- Ensure your WiFi network is 5G or 2.4G compatible.
- Verify the WiFi password entered during setup is correct.
- Check the device's proximity to the WiFi router. Signal strength may be an issue.
- Try resetting the device using the reset button (5) and re-attempting the WiFi configuration via the app.
- Znova zaženite usmerjevalnik WiFi.
- App Login Issues:
- Double-check your email and password.
- Poskrbite, da ima vaša mobilna naprava stabilno internetno povezavo.
- If you've forgotten your password, use the "Forgot Password" option in the app.
- Zagotovite, da je aplikacija posodobljena na najnovejšo različico.
- Netočni odčitki:
- Verify that the probes are securely connected to the device.
- Ensure the probes are placed correctly in the environment being monitored and are not obstructed.
- Check for any physical damage to the probes or cables.
- No Data Uploading:
- Confirm the device is connected to WiFi (check the WiFi icon on the display).
- Check the upload interval settings in the app; ensure it's not set to a very long period.
- Verify that the device has sufficient battery power.
If problems persist, please contact Elitech customer support for further assistance.
8. Specifikacije
| Specifikacija | Vrednost |
|---|---|
| Številka modela | RCW-800W-TDE-V2 |
| Znamka | Elitech |
| Območje merjenja temperature | -40℉ ~ 176℉ (-40℃ ~ 80℃) |
| WiFi povezljivost | 5G/2.4G |
| Vrsta baterije | Potrebne so 1 baterije AA (priložene) |
| Offline Record Capacity | 20,000 točk |
| Dimenzije paketa | 6.85 x 5.08 x 2.87 palcev |
| Teža predmeta | 1.01 funta |
| barva | Dual External Temp |
9. Garancija in podpora
For warranty information or technical support, please contact Elitech Technology Inc. directly. Their contact details can typically be found on their official website or through the Elitech iCold app. When contacting support, please have your product model number (RCW-800W-TDE-V2) and any relevant purchase information ready.
For common issues, refer to the troubleshooting section of this manual or the FAQ section on the Elitech website. Elitech also offers appointment-based technical support for setup assistance.