Uvod
This manual provides detailed instructions for the safe and efficient operation, setup, and maintenance of the Elitech LMG-10 Digital HVAC Manifold Gauge and the Elitech SVP-7 Intelligent HVAC Vacuum Pump. These tools are designed for professional HVAC applications, offering precision and ease of use for various tasks including pressure monitoring, vacuum testing, and refrigerant management.

Varnostne informacije
Always read and understand all safety warnings and instructions before operating the LMG-10 and SVP-7. Failure to follow these instructions may result in electric shock, fire, and/or serious injury.
- Pred uporabo se prepričajte, da so vse povezave varne.
- Do not operate in flammable environments.
- Nosite ustrezno osebno zaščitno opremo (OZO), vključno z zaščitnimi očali in rokavicami.
- Refer to local regulations for refrigerant handling and disposal.
- Pred kakršnim koli vzdrževanjem ali čiščenjem izklopite napajanje.

Komponente izdelka in večview
Elitech LMG-10 Digital HVAC Manifold Gauge

- LCD zaslon: Displays pressure, temperature, and other operational data.
- Gumbi za upravljanje: For mode selection, navigation, zeroing, and power.
- Kontrolno steklo: Allows visual inspection of refrigerant flow.
- Krmilni ventili: Regulate refrigerant flow.
- Refrigerant Hose Fittings: Connection points for refrigerant hoses.
- Refrigerant Hose Brackets: For organizing hoses.
- Temperature Probe Port: For connecting temperature clamps.
Elitech SVP-7 Intelligent HVAC Vacuum Pump

- Dovod zraka: Point of entry for air/refrigerant vapor.
- Okno za olje: Omogoča vizualni pregled nivoja in stanja olja.
- Zaslon: Shows vacuum status and operational data.
- Motor: Powers the pump mechanism.
- Čep za izpust olja: Za odvajanje rabljenega olja vakuumske črpalke.
- Ročaj: Za prenosljivost.
- Elektromagnetni ventil: Controls vacuum flow and prevents backflow.
- Rezervoar za olje: Reservoir for vacuum pump oil.
Nastavitev
Initial Setup of LMG-10 Digital Manifold Gauge
- Razpakiranje: Carefully remove the LMG-10 from its packaging. Inspect for any damage.
- Namestitev baterije: Open the battery compartment on the back of the unit. Insert the required batteries, ensuring correct polarity. Close the compartment securely.
- Vklop: Pritisnite in držite gumb za vklop, da vklopite enoto.
- Nastavitev na ničlo: Before use, ensure the manifold gauge is zeroed according to the instructions in the operating section.
Initial Setup of SVP-7 Intelligent HVAC Vacuum Pump
- Razpakiranje: Carefully remove the SVP-7 from its packaging. Inspect for any damage.
- Polnjenje olja: The SVP-7 comes with vacuum pump oil. Locate the oil fill port and fill the pump with the provided oil to the indicated level on the oil window. Do not overfill.
- Napajalni priključek: Priključite napajalni kabel v ustrezno električno vtičnico. Prepričajte se, da je glasnosttage ustreza zahtevam črpalke.
- Prenos aplikacije (neobvezno, vendar priporočljivo): Download the "Elitech Tools" app from the App Store (iOS) or Google Play Store (Android) for enhanced control and monitoring features.
Navodila za uporabo
Using the LMG-10 Digital Manifold Gauge
- Priključne cevi: Connect the appropriate refrigerant hoses to the LMG-10 fittings and to the HVAC system ports (low side, high side, and vacuum/refrigerant tank).
- Power On and Zero: Turn on the LMG-10. Press the "ZERO" button to calibrate the pressure sensors to atmospheric pressure before connecting to a system.
- Merjenje temperature: Attach the temperature clamps to the refrigerant lines to measure superheat and subcooling. The readings will display on the LCD screen.
- Spremljanje tlaka: The LCD screen will display real-time pressure readings for both high and low sides, along with corresponding saturation temperatures.
- Izbira načina: Use the "MODE" button to cycle through different measurement units (e.g., psi, kPa, bar) or display modes.
Using the SVP-7 Intelligent HVAC Vacuum Pump
- Povezovanje s sistemom: Connect the vacuum pump to the HVAC system via the manifold gauge or directly to the system's vacuum port.
- Vklop: Press the power button on the SVP-7 to start the pump.
- Spremljanje vakuuma: The SVP-7's display screen will show the current vacuum level. For precise monitoring, use the Elitech Tools app.
- Inteligentni nadzor: The pump features intelligent control of the motor and solenoid valve, which will open or close instantly according to the motor status, optimizing the evacuation process.
- Vacuum Leakage Test: The SVP-7 can monitor the process of pressure holding and vacuum leakage test precisely with temperature compensation. Refer to the app for detailed leakage test procedures.
- Izklopi: Once the desired vacuum level is achieved, close the system valves, then turn off the pump. Disconnect hoses carefully.
App Integration (Elitech Tools App)

The Elitech Tools App allows for remote control and detailed monitoring of both the LMG-10 and SVP-7. Key features include:
- Nadzor motorja: Remotely start and stop the SVP-7 vacuum pump.
- Data Logging & Exporting: Record and export vacuum and pressure data over time.
- Načini alarma: Set up alerts for specific pressure or vacuum thresholds.
- Vacuum Graph Display: Visualize vacuum changes in real-time.
- Nadzor temperature: View temperature readings from the LMG-10.
- Historical Data Checking: Access past operational data for analysis.
To connect, ensure Bluetooth is enabled on your mobile device and follow the in-app pairing instructions.
Vzdrževanje
LMG-10 Digital Manifold Gauge Maintenance
- Čiščenje: Enoto obrišite z mehko, damp krpo. Ne uporabljajte abrazivnih čistil ali topil.
- Shranjevanje: Store the LMG-10 in a dry, cool place when not in use. Remove batteries if storing for extended periods to prevent leakage.
- Kalibracija senzorja: Periodically check and recalibrate the pressure sensors as needed, especially if accuracy issues are suspected.
SVP-7 Intelligent HVAC Vacuum Pump Maintenance
- Preverjanje nivoja olja: Regularly check the oil level through the oil window. Maintain the oil level between the MIN and MAX marks.
- Menjava olja: Change the vacuum pump oil regularly, especially after each major job or if the oil appears cloudy or discolored. To change oil, drain old oil via the oil drain plug and refill with new, clean vacuum pump oil.
- Čiščenje: Keep the exterior of the pump clean. Ensure air vents are free from obstructions.
- Shranjevanje: Store the SVP-7 in a dry, well-ventilated area.
Odpravljanje težav
| Težava | Možen vzrok | rešitev |
|---|---|---|
| LMG-10 does not power on. | Prazne ali nepravilno vstavljene baterije. | Zamenjajte baterije; pazite na pravilno polarnost. |
| Inaccurate pressure readings on LMG-10. | Needs zeroing; sensor issue; temperature compensation error. | Perform zeroing procedure; contact support if issue persists. |
| SVP-7 not pulling vacuum effectively. | Low or contaminated oil; system leak; clogged air inlet. | Check/change oil; check system for leaks; clear air inlet. |
| SVP-7 is excessively noisy. | Low oil level; worn components. | Check and refill oil; if noise persists, contact support. |
| App not connecting to devices. | Bluetooth off; device not in pairing mode; app outdated. | Ensure Bluetooth is on; restart devices; update app. |
Specifikacije
| Funkcija | Podrobnost |
|---|---|
| Dimenzije izdelka | 18 x 13 x 20 palcev |
| Teža predmeta | 42 funta |
| Znamka | Elitech |
| Material | Plastika |
| LMG-10 Screen Size | 4 palcev |
| SVP-7 Vacuum Capacity | 7 CFM (kubičnih čevljev na minuto) |
| Združljivost aplikacij | iOS and Android (Elitech Tools App) |
Garancija in podpora
Elitech products are backed by a manufacturer's warranty. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Elitech website. For technical support, troubleshooting assistance, or service inquiries, please contact Elitech customer service.
Proizvajalec: Elitech
Webspletno mesto: www.elitech.com
Kontaktni podatki: Refer to the Elitech webNajnovejše kontaktne podatke najdete na spletnem mestu ali embalaži izdelka.





