KING KB2405-1-ECO2S-PLUS

KING KB ECO2S+ 5KW 240V Electronic Garage Heater Instruction Manual

Model: KB2405-1-ECO2S-PLUS

Znamka: KING

1. Uvod

The KING KB ECO2S+ series unit heater provides efficient and user-friendly heating for various spaces. This model, KB2405-1-ECO2S-PLUS, features a 5KW / 240V power output, 2-stage heating, and an integrated electronic thermostat with a remote control and remote temperature sensor for optimal comfort and energy savings. It is designed for use as primary or supplemental heat sources in warehouses, stores, or large garages.

Ključne značilnosti:

2. Pomembne varnostne informacije

Read all instructions before installing or using this heater. Failure to follow these instructions may result in electric shock, fire, property damage, or personal injury.

3. Vsebina paketa

Po odprtju paketa preverite, ali so vsi predmeti prisotni in nepoškodovani:

KING KB ECO2S+ heater unit, remote control, remote temperature sensor, and mounting bracket
Figure 1: Included components of the KING KB ECO2S+ heater package.

This image displays the main heater unit, a black remote control, a white remote temperature sensor, and a grey universal mounting bracket, all included in the product package.

4. Namestitev

4.1 Montaža grelnika

The universal mounting bracket allows for both wall and ceiling installation. Ensure the mounting surface is structurally sound to support the heater's weight (approximately 40 lbs). Use appropriate lag bolts or expansion bolts provided in the hardware pack.

  1. Attach the universal bracket to the desired wall or ceiling location using appropriate fasteners.
  2. Align the heater unit with the bracket and secure it using the large knobs on the sides, allowing for angle adjustment.
  3. Adjust the heater angle to direct airflow as needed. The bracket offers four adjustable positions.
Nazaj view of KING KB ECO2S+ heater showing the fan and mounting points
Slika 2: Zadaj view of the heater, illustrating the fan and mounting points for the bracket.

This image shows the back of the grey heater unit with a protective grill covering the fan. Mounting holes are visible on the sides for attaching the universal bracket.

4.2 Električna napeljava

This heater requires a 240V dedicated circuit. Installation must be performed by a licensed electrician. The 5KW model typically requires a 40-amp breaker and 4-8 AWG copper wire. Ensure all local electrical codes are followed.

  1. Odklop napajanja: Turn off power at the main circuit breaker before beginning any wiring.
  2. Predal za dostop do ožičenja: Locate and remove the single Phillips screw on the side panel to open the wiring compartment.
  3. Remove Knockout: Select an appropriate knockout on the side of the heater for your wiring. Use pliers to remove the knockout.
  4. Install Strain Relief: Insert the provided grommet with integral strain relief into the knockout hole.
  5. Povežite žice:
    • Connect the black wire to the L1 terminal.
    • Connect the red wire to the L2 terminal.
    • Connect the green (ground) wire to the grounding screw.
    Ensure all wires are securely tightened and that no insulation is under the terminals.
  6. Varno ožičenje: Tighten the strain relief to prevent the wire from pulling out and to protect the wiring from damage.
  7. Zapri predal: Reattach the access panel with the Phillips screw.
  8. Obnovi moč: Vklopite napajanje na glavnem odklopniku.
Internal wiring compartment of the KING KB ECO2S+ heater showing terminals and circuit board
Figure 3: Internal wiring connections for the heater.

This image shows the internal wiring compartment of the heater with various colored wires connected to terminals (L1, L2, and ground) and a circuit board. A label indicates "Red Wire L2" and "Black Wire L1" for 240V, 4-8AWG connections.

Video 1: This video demonstrates the electrical wiring process for the KING KB ECO2S+ heater, showing how to connect the power cable to the internal terminals and secure it with a strain relief. It also highlights the 2-stage heating feature and remote temperature sensing.

4.3 External Thermostat Switch

On the back of the heater, there is a toggle switch to select between the built-in thermostat (setting I) and an external thermostat (setting II). For most applications using the integrated controls, ensure the switch is set to 'I'. If connecting to an external 24V thermostat (e.g., Nest), set the switch to 'II' and ensure proper wiring by a licensed electrician.

5. Navodila za uporabo

5.1 Začetni vklop

Upon initial power-up, the unit will beep, and the display will show the current room temperature. This indicates correct voltage in napajanje.

5.2 Nadzorna plošča in daljinski upravljalnik

The heater can be operated via the integrated control panel or the included remote control. The remote control offers convenient access to all functions from a distance.

Spredaj view of KING KB ECO2S+ heater showing the control panel
Slika 4: Spredaj view of the heater with the control panel visible.

This image shows the front of the grey heater unit with horizontal louvers and a digital control panel at the bottom. The control panel has buttons for Power, Mode, Start/Stop, and Up/Down arrows, along with a digital temperature display.

5.3 Načini delovanja

Press the 'Mode' button to cycle through the available operating modes:

5.4 Nastavitev temperature

Use the Up/Down arrow buttons on the control panel or remote to set your desired temperature. The heater will maintain this temperature automatically.

5.5 Funkcija časovnika

The timer mode allows you to set the heater to run for a predetermined length of time, after which it will automatically shut off. This feature helps conserve energy and provides convenience.

6. Vzdrževanje

Redno vzdrževanje zagotavlja optimalno delovanje in dolgo življenjsko dobo vašega grelnika. Pred kakršnim koli vzdrževanjem vedno izklopite napajanje.

7. Odpravljanje težav

Če vaš grelec ne deluje pravilno, si oglejte naslednje pogoste težave in rešitve:

TežavaMožen vzrokrešitev
Heater does not turn on / No display.No power to the unit or incorrect voltage.Check circuit breaker. Ensure 240V power is supplied. Verify wiring connections are secure.
Grelec je vklopljen, vendar ne proizvaja toplote.Thermostat switch set to external, or external thermostat not calling for heat.Ensure the external thermostat switch on the back of the unit is set to 'I' for internal thermostat control. If using an external thermostat, check its settings.
Nezadostno ogrevanje.Incorrect mode selected, or obstructions.Select 'High Heat' mode. Ensure air inlets/outlets are clear. Check louvers are directed appropriately.
Daljinski upravljalnik ne deluje.Prazne baterije ali ovira.Replace remote control batteries. Ensure no obstructions between remote and heater.

8. Specifikacije

Chart showing recommended garage heater wattage for different garage sizes
Figure 5: Recommended wattage for various garage sizes.

This chart provides guidance on selecting the appropriate heater wattage based on garage size (1-car to 4-car garages), square footage, BTU, CFM, and amperage. The 5KW model is suitable for 1-car garages up to 450 sq. ft.

9. Garancija in podpora

For specific warranty details, please refer to the documentation included with your product or contact KING customer support. General product protection plans may be available for purchase separately.

Visit the official KING Store for more information: KING Store

Povezani dokumenti - KB2405-1-ECO2S-PLUS

Prejview Kompaktni grelnik King KBP ECO2S+ serije - energetsko učinkovit 2-Stage Ogrevanje
Podrobne informacije o kompaktnem grelniku King KBP ECO2S+ serije z energetsko varčnim elektronskim krmiljenjem ECO2S+, 2-stagogrevanje, daljinsko zaznavanje temperature in vsestranske možnosti namestitve. Vključuje specifikacije, informacije za naročilo in inženirske podrobnosti.
Prejview Navodila za namestitev in vzdrževanje grelnikov serije King LPW-ECO
Celovit vodnik za namestitev, upravljanje in vzdrževanje elektronskih grelnikov serije King LPW-ECO, vključno z varnostnimi navodili, shemami ožičenja, nastavitvijo daljinskega senzorja in odpravljanjem težav.
Prejview Priročnik za namestitev in vzdrževanje King LPW ECO2S PRO s pametnim krmilnikom
This comprehensive manual provides detailed instructions for the installation, maintenance, and operation of the King LPW ECO2S PRO series electric heaters. Learn about safe installation, programming the 7-day ECO PRO controller, wiring, troubleshooting, and warranty information for optimal comfort and energy savings.
Prejview Navodila za namestitev in uporabo 7-dnevnega programabilnega krmilnika King PX ECO2S PRO
Celovit vodnik za 7-dnevni programabilni 2-S King PX ECO2S PROtagElektronski krmilnik z daljinskim zaznavanjem temperature. Vključuje varnostna navodila, namestitev, ožičenje, vodotagizbira, združevanje krmilnikov, nastavitev, načini delovanja, programiranje, odpravljanje težav, vzdrževanje in izbirna integracija senzorjev.
Prejview Grelnik King LPW ECO2S PRO: Navodila za namestitev, vzdrževanje in uporabo
Celovit vodnik za King LPW ECO2S PRO 7-dnevni programabilni 2-StagElektronski grelec z daljinskim regulatorjem temperature. Vključuje namestitev, ožičenje, vodotaginformacije o izbiri, nastavitvi, delovanju, vzdrževanju, odpravljanju težav in garanciji.
Prejview Prenosni grelec za delavnice King PSH2440TB: Priročnik za namestitev, uporabo in varnost
Ta obsežen priročnik vsebuje bistvene informacije o prenosnem grelniku za delavnice King PSH2440TB, vključno z namestitvijo, varnostnimi smernicami, navodili za uporabo, nasveti za vzdrževanje in rešitvami za odpravljanje težav. Zasnovan je za uporabo v garaži in delavnici, ima moč 3750 W in deluje na 240 V.