BFT P125002

Navodila za uporabo kompleta za rezervno napajanje z baterijo BFT SB-BAT P125002 24V DC

For BFT Gate Opener Systems

1. Uvod

This manual provides essential instructions for the installation, operation, and maintenance of the BFT SB-BAT P125002 24V DC Battery Backup Kit. This kit is designed to ensure continuous operation of compatible BFT gate openers during temporary power outages. Please read this manual thoroughly before proceeding with installation or use.

2. Izdelek je končanview

The BFT SB-BAT P125002 is a 24V DC battery backup system that integrates with specific BFT gate operators. It includes a smart charger board that manages battery charging when main power is available and automatically switches to battery power when the main supply is interrupted.

BFT SB-BAT P125002 Battery Backup Kit components in box

Slika 1: Konecview of the BFT SB-BAT P125002 Battery Backup Kit, showing the product box, two batteries, wiring, and mounting hardware.

2.1. Komponente kompleta

Individual components of the BFT SB-BAT P125002 Battery Backup Kit

Slika 2: Podrobno view of the BFT SB-BAT P125002 kit components, including batteries, wiring, mounting brackets, and the battery holder.

3. Združljivost

This battery backup system is compatible with the following BFT gate operator series:

Ensure your gate operator model is listed above for proper functionality.

4. Nastavitev in namestitev

Installation of the BFT SB-BAT P125002 kit is designed to be straightforward. However, it is recommended that installation be performed by a qualified technician to ensure safety and correct operation. Always disconnect main power to the gate operator before beginning installation.

4.1. Varnostni ukrepi

4.2. Koraki namestitve (splošna navodila)

  1. Mount the Battery Holder: Secure the battery holder/mounting base within the gate operator's control box or an appropriate enclosure using the provided mounting brackets and fasteners. Ensure it is stable and accessible.
  2. Vstavite baterije: Place the two 12V 1.2Ah batteries into the battery holder.
  3. Povežite baterije: Connect the batteries in series to achieve 24V DC, following the wiring diagram provided with your specific gate operator or the kit's smart charger board. Ensure correct polarity.
  4. Connect Smart Charger Board: Integrate the smart charger board into the gate operator's control unit. Refer to your gate operator's manual for the specific connection points for the battery backup system.
  5. Varno ožičenje: Route and secure all wiring to prevent pinching or damage.
  6. Obnovi moč: Once all connections are verified and secure, restore main power to the gate operator. The smart charger board will begin charging the batteries.
  7. Testni sistem: Perform a power outage simulation to verify the battery backup system activates correctly and powers the gate operator.

5. Navodila za uporabo

The BFT SB-BAT P125002 operates automatically once installed correctly.

5.1. Normal Operation (Power On)

When main power is supplied to the gate operator, the smart charger board within the SB-BAT kit continuously monitors the battery charge level. It will charge the batteries as needed to maintain them at full capacity.

5.2. Power Outage Operation (Power Off)

V primeru izpada električne energijetage, the smart charger board automatically detects the loss of main power and switches the gate operator to battery power. The gate operator will then function normally using the stored energy in the batteries. The duration of operation on battery power depends on the frequency of gate usage and the charge level of the batteries.

6. Vzdrževanje

Regular maintenance ensures the longevity and reliability of your battery backup system.

6.1. Battery Recharging

Po moči otage, once main power is restored, the smart charger board will automatically begin recharging the batteries. A full recharge typically takes 12 do 14 ur. It is important to allow sufficient time for batteries to fully recharge after use.

6.2. Fuse Check

Sistem vključuje a 20A varovalka for protection. If the battery backup system fails to operate or charge, inspect the fuse for continuity. Replace with a fuse of the exact same rating if necessary. Always disconnect power before checking or replacing fuses.

6.3. Življenjska doba baterije in zamenjava

Batteries have a finite lifespan. Periodically test the system by simulating a power outage to ensure batteries hold a charge and can power the gate operator. If performance degrades significantly, consider replacing the batteries. Use only recommended replacement batteries (2x 12V 1.2Ah sealed lead-acid).

7. Odpravljanje težav

If your BFT SB-BAT P125002 battery backup system is not functioning as expected, consider the following:

For persistent issues, contact BFT technical support or a qualified service technician.

8. Specifikacije

FunkcijaSpecifikacija
Številka modelaP125002
Vrsta baterijeZatesnjena svinčeno-kislinska
Kapaciteta baterije2x (12V 1.2Ah)
Izhodna voltage24V DC (nominal)
Charge Voltage27.2 V
Polnilni tok130mA
Čas polnjenja baterije12-14 ur
Exhausted Battery Protection Threshold20.4 V
Ocena varovalk20A
Delovna temperaturaData detected with external temperature of: 25°C (77°F)

9. Garancija in podpora

For warranty information, please refer to the documentation provided with your original purchase or contact BFT customer support directly. For technical assistance, installation queries, or troubleshooting beyond the scope of this manual, please contact your authorized BFT dealer or BFT technical support.

BFT Contact Information: Please visit the official BFT webspletno mesto za najnovejše kontaktne podatke in vire za podporo.