Uvod
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your FibroPool 2 HP Swimming Pool Pump (Model FP200). Please read this manual thoroughly before installation and operation to ensure proper use and to prevent damage or injury.
The FibroPool FP200 is a high-efficiency single-speed motor pump designed for in-ground pools and spas. It features a durable, corrosion-proof construction and is engineered for reliable performance.
Varnostne informacije
Always observe basic safety precautions when installing and operating this electrical equipment. Failure to follow instructions can result in serious injury or death.
- Ensure the pump is connected to a 240-volt, 60 Hz power supply only. It is not convertible to 120 volts.
- Namestitev mora opraviti usposobljen strokovnjak in mora biti v skladu z vsemi lokalnimi in nacionalnimi električnimi in vodovodnimi predpisi.
- Pred kakršnim koli servisiranjem ali vzdrževanjem vedno izklopite napajanje črpalke.
- Do not run the pump dry. Ensure the pump is primed with water before starting.
- Otroke držite stran od črpalke in bazenske opreme.
- Do not operate the pump if any parts are damaged or missing.
Konec izdelkaview
The FibroPool FP200 pump is engineered for optimal performance and longevity. Key features include:
- 2 horsepower motor, pushing up to 8100 GPH at 3450 RPM.
- High-efficiency single-speed motor designed to reduce energy consumption.
- Durable, weatherproof chassis suitable for various environments.
- Integrated pedestal base for stable mounting.
- Super-sized 124 cubic-inch strainer basket with a clear twist-lock lid for easy inspection and cleaning.
- 2-inch unions included for simplified installation and servicing.

Slika 1: stran view of the FibroPool FP200 Swimming Pool Pump, showing the motor and pump housing.

Slika 2: Nasprotna stran view of the FibroPool FP200 Swimming Pool Pump, highlighting the clear strainer lid.
Namestitev
Proper installation is crucial for the pump's performance and longevity. It is recommended that installation be performed by a certified pool technician or electrician.
Izbira mesta
- Install the pump as close to the pool as possible to minimize friction loss from plumbing.
- Ensure the location is well-ventilated and protected from direct sunlight and excessive moisture.
- Provide adequate space around the pump for routine maintenance and servicing.
- Mount the pump on a solid, level base to prevent vibration and noise. The integrated pedestal base provides stability.
Vodovodni priključki
- The pump is equipped with 2-inch unions for easy connection to your existing plumbing system.
- Use appropriate PVC cement and primer for secure, leak-free connections.
- Ensure all plumbing is properly supported to avoid strain on the pump.
Električne povezave
OPOZORILO: Electrical wiring should only be performed by a licensed electrician.
- The FibroPool FP200 operates on 240 volts, 60 Hz. Verify your power supply matches these requirements.
- Connect the pump to a dedicated circuit protected by a Ground Fault Circuit Interrupter (GFCI).
- The pump includes a 6-foot weatherproof power cable. Ensure all connections are secure and weatherproof.
- Refer to local electrical codes for specific wiring requirements.

Slika 3: Zadaj view of the FibroPool FP200 pump, showing the electrical connection box and wiring.
Navodila za uporabo
Polnjenje črpalke
Pred prvim zagonom črpalke ali po izpraznitvi zaradi vzdrževanja je treba črpalko napolniti.
- Ensure all valves are open to allow water flow from the pool to the pump.
- Remove the clear twist-lock lid from the strainer basket.
- Fill the strainer basket with water until it overflows.
- Replace the lid, ensuring it is securely twisted and sealed.
- Turn on the pump. The pump should prime within a few minutes. If not, turn off the pump, re-prime, and check for air leaks in the suction line.
Normalno delovanje
- Once primed, the pump will circulate water through your pool system.
- Monitor the pressure gauge on your filter system to ensure it is within the normal operating range.
- The clear top lid allows for easy visual inspection of the strainer basket to determine when cleaning is needed.
Vzdrževanje
Regular maintenance ensures the longevity and efficient operation of your FibroPool pump.
Strainer Basket Cleaning
The super-sized 124 cubic-inch basket has extra leaf-holding capacity, extending time between cleanings. However, regular inspection is recommended.
- Izklopite črpalko in odklopite napajanje.
- Twist and remove the clear lid from the strainer housing.
- Odstranite košaro in izpraznite morebitne odpadke.
- Koš temeljito sperite z vodo.
- Inspect the O-ring on the lid for cracks or wear. Replace if necessary.
- Return the basket to the housing, ensuring it is seated correctly.
- Replace the lid, twisting it securely to create a watertight seal.
- Po potrebi pred ponovnim zagonom črpalko ponovno napolnite.
Zimovanje
In areas subject to freezing temperatures, proper winterization is essential to prevent damage.
- Drain all water from the pump by removing the drain plugs.
- Store the pump in a dry, protected area if possible.
- Consult a pool professional for comprehensive winterization procedures for your entire pool system.
Odpravljanje težav
This section provides solutions to common issues you may encounter with your FibroPool pump.
| Težava | Možen vzrok | rešitev |
|---|---|---|
| Črpalka se ne zažene | No power, tripped breaker/GFCI, faulty wiring, motor issue. | Check power supply, reset breaker/GFCI. Verify electrical connections. If motor hums but doesn't start, contact a qualified technician. |
| Pump runs but does not prime or has low flow | Air leak in suction line, clogged strainer basket, low water level in pool, closed valves, impeller obstruction. | Check and seal all suction line connections. Clean strainer basket. Ensure adequate pool water level. Open all necessary valves. Inspect impeller for debris. |
| Prekomerni hrup ali tresljaji | Air leak, cavitation, loose mounting, worn bearings. | Check for air leaks. Ensure pump is properly primed. Tighten mounting bolts. If noise persists, motor bearings may be worn; contact service. |
| Voda pušča iz črpalke | Loose plumbing connections, worn shaft seal, damaged O-rings. | Tighten plumbing connections. Inspect and replace O-rings on strainer lid and unions. A leaking shaft seal requires professional service. |
Specifikacije
Detailed technical specifications for the FibroPool 2 HP Swimming Pool Pump FP200.
| Atribut | Vrednost |
|---|---|
| Znamka | FibroPool |
| Številka modela | FP200 |
| Konjska moč | 2 KM |
| voltage | 240 volta |
| Pogostost | 60 Hz |
| Wattage | 1.5 KW |
| Največji pretok | 135 galon na minuto (8100 GPH) |
| RPM | 3450 RPM |
| Material | Aluminum (Motor), Heavy Duty Plastic (Housing) |
| Teža predmeta | 34.9 funtov |
| Dimenzije paketa | 25 x 14.5 x 11.5 palcev |
| Nivo zvoka | 45 dB |
| UPC | 850013473021 |

Figure 4: Performance Curve Chart. The FP200 curve illustrates the relationship between pump head (pressure) and flow rate.
Garancija in podpora
For warranty information, technical support, or service inquiries, please contact FibroPool directly. Keep your purchase receipt as proof of purchase.
While specific warranty details are not provided in this manual, FibroPool is committed to providing quality products and customer satisfaction. For the most current warranty terms and conditions, please visit the official FibroPool webali se obrnite na njihov oddelek za pomoč uporabnikom.
You can often find contact information on the product packaging, the manufacturer's webspletnem mestu ali prek prodajalca, kjer je bil izdelek kupljen.



