First Alert 7020BSL

First Alert BRK 7020BSL Hardwired Smoke Detector with LED Strobe Light for Hearing Impaired

Navodila za uporabo

Uvod

This manual provides comprehensive instructions for the installation, operation, and maintenance of your First Alert BRK 7020BSL Hardwired Smoke Detector with LED Strobe Light. This device is designed to provide both audible and visual warnings in the event of smoke or fire, making it particularly beneficial for individuals with hearing impairments. Please read this manual thoroughly before installation and keep it for future reference.

Lastnosti izdelka

Vsebina paketa

Your First Alert BRK 7020BSL package should contain the following items:

First Alert BRK 7020BSL Smoke Detector with wiring harness

Image: First Alert BRK 7020BSL smoke detector with its wiring harness, showing the main unit and the separate wiring component.

Pomembne varnostne informacije

Please read and understand all instructions before installing and operating this smoke detector. Failure to follow these instructions may result in property damage, injury, or death.

Nastavitev in namestitev

Follow these steps to properly install your First Alert BRK 7020BSL smoke detector:

  1. Ugasniti: Before starting, ensure the power to the circuit where you will install the alarm is turned off at the main electrical panel.
  2. Remove Old Alarm (if applicable): Carefully disconnect and remove any existing smoke alarm from the junction box.
  3. Namestitev montažnega nosilca:
    • Attach the mounting bracket to the electrical junction box using the provided screws. Ensure it is securely fastened.
    • If no junction box is present, use the provided screws and anchors to mount the bracket directly to the ceiling or wall.
    Stran view of First Alert BRK 7020BSL Smoke Detector

    Slika: Stranski profesionalecfile of the First Alert BRK 7020BSL smoke detector, showing its compact design.

  4. Žične povezave:
    • Connect the white wire from the alarm's wiring harness to the neutral (white) wire from your household wiring using a wire nut.
    • Connect the black wire from the alarm's wiring harness to the hot (black) wire from your household wiring using a wire nut.
    • If interconnecting multiple alarms, connect the orange wire from the alarm's wiring harness to the interconnect (orange or red) wire from your household wiring. If not interconnecting, cap the orange wire with a wire nut.
    • Connect the ground wire from the household wiring to the ground screw on the mounting bracket or junction box.
  5. Pritrditev alarma na nosilec: Plug the wiring harness into the back of the smoke detector. Align the alarm with the mounting bracket and twist clockwise until it locks securely into place.
  6. Vklop: Restore power to the circuit at the main electrical panel.
  7. Testna enota: Press and hold the Test/Silence button on the front of the alarm until the alarm sounds and the strobe light flashes. This confirms proper operation.

Video: Official First Alert video demonstrating the installation process for hardwired smoke alarms. This video provides a visual guide to connecting the wiring and mounting the alarm.

Navodila za uporabo

Once installed and powered, your First Alert BRK 7020BSL smoke detector operates automatically. Familiarize yourself with its indicators and functions:

Spredaj view of First Alert BRK 7020BSL Smoke Detector

Slika: spredaj view of the First Alert BRK 7020BSL smoke detector, highlighting the test/silence button and the LED strobe light.

Vzdrževanje

Redno vzdrževanje zagotavlja, da vaš detektor dima ostane v optimalnem delovnem stanju.

Odpravljanje težav

TežavaMožen vzrokrešitev
Alarm sounds frequently without apparent smoke.Moteč alarm zaradi kuhalnih hlapov, pare ali prahu.Press the Test/Silence button to temporarily silence. Clean the alarm monthly. Relocate if nuisance alarms persist.
Alarm zapiska enkrat na minuto.Opozorilo o nizki bateriji.The sealed 10-year battery is at the end of its life. Replace the entire smoke detector unit.
Med preizkusom se alarm ne oglasi.No power, faulty unit, or dead battery.Ensure AC power is on. Check wiring connections. If chirping, replace the unit. If no power or chirping, replace the unit.
Strobe light does not flash during alarm.Faulty strobe light or unit.Replace the entire smoke detector unit.
Alarm is past its 10-year lifespan.End-of-life for the unit.Replace the entire smoke detector unit immediately.

Specifikacije

Številka modelaBRK 7020BSL
Vir napajanja120V AC Hardwired with Sealed 10-Year Lithium Metal Battery Backup
Vrsta senzorjaFotoelektrična
Strobe Light Output177 Candela (LED)
Glasnost alarma85 dB na 10 čevljev
Delovna temperatura40°F (4.4°C) do 100°F (37.8°C)
Delovna vlažnost10% do 95% relativne vlažnosti (brez kondenzacije)
DimenzijePremer 5.2 cm x globina 2.3 cm
TežaPribližno 13.8 unč
Zmogljivost medsebojnega povezovanjaUp to 18 compatible devices (12 smoke alarms)

Garancija in podpora

Informacije o garanciji: First Alert warrants this product to be free from defects in material and workmanship for a period of ten (10) years from the date of purchase. This warranty extends to the original retail purchaser only. Proof of original sales receipt is required for warranty claims. This warranty does not cover damage resulting from accident, misuse, abuse, lack of reasonable care of the product, or any other use not in accordance with the instructions. For full warranty details, please refer to the documentation included with your product or visit the official First Alert webmesto.

Podpora strankam: For technical assistance, troubleshooting, or general inquiries, please contact First Alert customer support. Contact information can typically be found on the product packaging or the official First Alert website. Please have your model number (BRK 7020BSL) and date of purchase available when contacting support.