The KEYSIGHT U1242C is a robust and reliable handheld digital multimeter (DMM) designed for professional and industrial use. It offers high accuracy, durability, and advanced features for various electrical measurements. This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your U1242C DMM.
Glavne lastnosti vključujejo:
WARNING: Read and understand all safety instructions before operating this device. Failure to follow these instructions may result in injury or damage to the meter.

This image displays the front of the KEYSIGHT U1242C Digital Multimeter, showing its large orange casing, the dual display screen, the rotary dial for function selection, and the input jacks for test leads. Various buttons for functions like Max/Min, Hz, Log, Hold, and Range are visible around the display.

Ta slika prikazuje stranskega profesionalcafile of the KEYSIGHT U1242C Digital Multimeter, highlighting its ergonomic design and the textured grip on the orange casing. The side view emphasizes the compact and robust build of the device.

This image presents the back of the KEYSIGHT U1242C Digital Multimeter, revealing the battery compartment cover, the kickstand for hands-free operation, and the product label with model and serial number information. The robust construction of the casing is also evident.
Always connect the test leads to the appropriate input jacks for the measurement you intend to perform. Incorrect connection can lead to damage to the meter or personal injury.
This section outlines the basic steps for performing common measurements with your U1242C DMM.
CAUTION: Never connect the meter in parallel with a voltagvir pri merjenju toka. To lahko pregori varovalko ali poškoduje merilnik.
The U1242C supports data logging. Refer to the detailed user manual for specific instructions on activating and managing data logging functions, including connecting to a PC with the software bundle for extended logging capabilities.
Obrišite pokrov merilnikaasing z oglasomamp krpo in blagim detergentom. Ne uporabljajte abrazivnih sredstev ali topil. Pred uporabo se prepričajte, da je merilnik popolnoma suh.
When the battery indicator appears on the display, replace the batteries as described in Section 4.1. Prompt battery replacement ensures accurate readings and proper operation.
WARNING: Always replace blown fuses with fuses of the exact same type and rating to maintain safety and performance.
The U1242C is factory calibrated. For continued accuracy, periodic calibration by a qualified service center is recommended. Refer to KEYSIGHT's official support channels for calibration services.
| Težava | Možen vzrok | rešitev |
|---|---|---|
| Merilnik se ne vklopi | Prazne ali nepravilno nameščene baterije | Zamenjajte baterije, preverite polarnost |
| No reading or "OL" (Overload) displayed | Incorrect function selected; Open circuit; Input exceeds range | Select correct function; Check circuit continuity; Select higher range or auto-range |
| Netočni odčitki | Low battery; Dirty test leads; Environmental interference; Needs calibration | Replace battery; Clean leads; Move away from interference; Consider calibration |
| Merjenje toka ne deluje | Blown fuse; Incorrect lead connection; Meter not in series | Check/replace fuse; Verify lead connection; Ensure meter is in series with circuit |
| Funkcija | Specifikacija |
|---|---|
| Številka modela | U1242C |
| Zaslon šteje | 50,000 |
| Basic DC Voltage Natančnost | 0.03 % |
| AC merjenje | Pravi RMS |
| Ocena zaščite pred vdorom (IP). | IP 67 |
| Zaščita pred padci | Do 3 metrov (10 čevljev) |
| Vir napajanja | Napajanje na baterije |
| Teža predmeta | 1 funt (16 unč) |
| Proizvajalec | KEYSIGHT |
| Prvič na voljo | 22. maj 2018 |
Keysight Technologies products are classified as industrial monitoring and control equipment designed exclusively for professional or industrial use and related training programs. Keysight products are designed and certified to meet national industrial safety standards (such as Electrical Equipment for Measurement, Control and Laboratory Use) where products are sold solely for use by trained professionals. Keysight products are not intended for consumer use in a residential setting and may not meet consumer level standards for EMC and other regulated radiated emissions. Keysight products are intended for use in the country where the product was originally sold.
For technical assistance, service, or warranty claims, please contact KEYSIGHT customer support through their official website or authorized service centers. Provide your product model number (U1242C) and serial number when seeking support.
![]() |
Keysight U1231A/U1232A/U1233A Handheld Multimeter Quick Start Guide A quick start guide for Keysight U1231A, U1232A, and U1233A handheld multimeters, covering setup, operation, and basic measurements. |
![]() |
Keysight U1253B True RMS OLED Multimeter User's and Service Guide Comprehensive user and service guide for the Keysight U1253B True RMS OLED Multimeter, covering safety, environmental conditions, features, measurements, maintenance, and specifications. |
![]() |
Keysight U1253B True RMS OLED Multimeter Quick Start Guide Quick start guide for the Keysight U1253B True RMS OLED Multimeter, covering setup, features, and basic measurements like voltage, current, resistance, capacitance, temperature, frequency, and square wave output. |
![]() |
Digitalni multimeter Keysight Truevolt serije: Navodila za uporabo in servisiranje Celovit priročnik za upravljanje in servisiranje digitalnih multimetrov Keysight serije Truevolt, ki zajema funkcije, meritve, odpravljanje težav in kalibracijo. |
![]() |
Vodnik za hiter začetek modularnih izdelkov in sistemov Keysight USB Naučite se namestiti in konfigurirati modularne izdelke in sisteme USB podjetja Keysight s tem obsežnim priročnikom za hiter začetek, ki zajema bistvene korake nastavitve in funkcije za testne in merilne aplikacije. |
![]() |
Keysight U1731C/U1732C/U1733C Handheld LCR Meter User's Guide Comprehensive user's guide for the Keysight U1731C, U1732C, and U1733C Handheld LCR Meters. Learn about features, setup, measurements, and safety precautions for accurate component testing. |