1. Uvod
This user manual provides detailed instructions for the safe and effective operation of your Jumper Medical Infrared Ear Thermometer, Model JPD-FR301. This device is designed for accurate body temperature measurement in the ear canal for all ages, including infants, children, and adults.
Pred prvo uporabo natančno preberite ta priročnik in ga shranite za poznejšo uporabo.
2. Značilnosti izdelka
- Digital Infrared (IR) Ear Thermometer with protective cap.
- Fast 1-second measurement for quick results.
- Acoustic fever alarm for elevated temperatures (> 37.5 °C).
- Memory storage for the last 20 measurement readings.
- Switchable temperature display between Celsius (°C) and Fahrenheit (°F).
- Ergonomic design for comfortable handling and use.
- High sensitivity for maximum precision.
- Meets high hygienic standards.
- Certified with CE, FDA, ISO 13485 + AC:2012, ISO 10993-1, ISO 10993-10, Norm IEC 60601-1-2, and conforms to the Medical Devices Directive - MDD (EU).

Slika 2.1: The Jumper Medical Infrared Ear Thermometer held in a hand, showcasing its ergonomic shape and the clear LCD display.
3. Get to Know Your Product (Components)

Slika 3.1: Labeled diagram of the JPD-FR301 thermometer components.
- Gumb za merjenje: Used to initiate a temperature measurement.
- LCD zaslon: Shows temperature readings, mode indicators, and battery status.
- Senzor: The infrared sensor located at the tip for accurate ear temperature detection.
- Pokrov baterije: Protects the battery compartment.
- Ear cap case: Storage for disposable ear caps.
- Disposable ear caps: Hygienic covers for the sensor.
- Zgornji pokrov: Part of the ear cap case.
- Zadnji pokrov: Part of the ear cap case.
4. Vsebina embalaže
Po odprtju paketa preverite, ali so vsi spodaj navedeni elementi prisotni in v dobrem stanju:
- Jumper Medical Infrared Ear Thermometer unit (JPD-FR301)
- Pouch or storage bag
- Ear cap case with disposable ear caps
- 2 pcs of AAA battery

Slika 4.1: All items included in the product packaging.
5. Nastavitev
5.1 Namestitev baterije
The thermometer requires 2 AAA batteries for operation. To install or replace batteries:
- Locate the battery cover (4) on the back of the thermometer.
- Odprite pokrov baterije.
- Vstavite dve bateriji AAA in pazite na pravilno polarnost (+ in -), kot je označeno v notranjosti predala.
- Pokrov baterije trdno zaprite, dokler se ne zaskoči.
5.2 Attaching/Using Ear Cap Case
The ear cap case (5) holds disposable ear caps (6) for hygienic use. Always use a new, undamaged ear cap for each measurement.

Slika 5.1: Steps for handling the ear cap case and disposable ear caps.
- To open the ear cap case, gently lift the top cover (7) or slide the rear cover (8).
- Take out a disposable ear cap.
- Carefully place the ear cap onto the sensor (3) of the thermometer until it is securely fitted.
- After use, dispose of the used ear cap properly.
6. Navodila za uporabo
6.1 Merjenje
- Ensure a new, clean disposable ear cap is securely attached to the sensor.
- Press the "START" (Measuring button 1) to turn on the thermometer. The display will show the last measurement or a standby indicator.
- Gently insert the sensor tip with the ear cap into the ear canal. For accurate readings, ensure the tip is pointing towards the eardrum.
- Press the "START" button again to initiate the measurement.
- The measurement will be completed in approximately 1 second, and the result will be displayed on the LCD (2).
- If the temperature is elevated (fever alarm), an audible alert will sound.
- The thermometer will automatically store the reading in its memory.
- Remove the thermometer from the ear and dispose of the used ear cap.
6.2 Preklapljanje med °C in °F
To switch the temperature unit between Celsius (°C) and Fahrenheit (°F):
- With the thermometer turned off, press and hold the "START" button for approximately 5 seconds until the unit changes on the display.
- Release the button. The new unit will be set for future measurements.
6.3 Priklic spomina
The thermometer stores the last 20 measurement readings. To recall them:
- Vklopite termometer.
- Briefly press the "START" button repeatedly to cycle through the stored readings. Each press will display the next previous reading.
7. Vzdrževanje
7.1 Čiščenje termometra
- Always clean the thermometer after each use, especially the sensor area.
- Rahlo uporabite mehko krpo dampened with 70% isopropyl alcohol to wipe the sensor and the body of the thermometer.
- Termometra ne potapljajte v vodo ali katero koli drugo tekočino.
- Pred shranjevanjem pustite, da se termometer popolnoma posuši na zraku.
- Ne uporabljajte abrazivnih čistil ali močnih kemikalij.
7.2 Shranjevanje
Store the thermometer in its original pouch or the ear cap case in a cool, dry place, away from direct sunlight and extreme temperatures.
If the thermometer will not be used for an extended period, remove the batteries to prevent leakage and damage.
7.3 Pogoji delovanja in shranjevanja

Slika 7.1: Recommended environmental conditions for operation and storage.
Operating Environment Conditions:
- Temperatura: +10°C ~ +40°C (50°F ~ 104°F)
- Zračni tlak: 86 kPa ~ 106 kPa
- Vlažnost: 15-85 % RH, brez kondenzacije
Storage & Transportation Conditions:
- Temperatura: -10°C ~ +50°C (14°F ~ 122°F)
- Zračni tlak: 50 kPa ~ 106 kPa
- Vlažnost: <93% RH, brez kondenzacije
8. Odpravljanje težav
| Težava | Možen vzrok | rešitev |
|---|---|---|
| Termometer se ne vklopi. | Baterije so prazne ali nepravilno vstavljene. | Baterije zamenjajte z novimi baterijami AAA in pri tem pazite na pravilno polarnost. |
| Netočni odčitki. | Used or damaged ear cap; sensor dirty; improper insertion into ear canal; extreme environmental conditions. | Use a new, clean ear cap. Clean the sensor. Ensure correct insertion. Operate within specified temperature and humidity ranges. |
| Prikazano je "Lo" ali "Hi". | Temperatura je zunaj merljivega območja. | Ensure the thermometer is used in the correct operating temperature range and the subject's temperature is within human body temperature limits. |
| Fever alarm sounds frequently. | Subject's temperature is consistently above 37.5 °C (99.5 °F). | This indicates an elevated temperature. Consult a medical professional if fever persists. |
9. Specifikacije
| Funkcija | Podrobnost |
|---|---|
| Model: | JPD-FR301 |
| Vrsta izdelka: | Infrardeči termometer za uho |
| vir energije: | 2 x AAA Batteries (Battery-operated) |
| Čas merjenja: | 1 sekundo |
| Kapaciteta pomnilnika: | 20 branj |
| Enote za temperaturo: | Preklop med Celzijem (°C) in Fahrenheitom (°F) |
| Material: | Plastika |
| starostna skupina: | Child and Adult |
| UPC: | 635833227234 |
| Certifikati: | CE, FDA, ISO 13485 + AC:2012, ISO 10993-1, ISO 10993-10, Norm IEC 60601-1-2, MDD (EU) |
| Dimenzije embalaže: | 19.4 x 13.2 x 6.4 cm |
| Teža: | 300 Grams (packaged) |
10. Garancija in podpora
For warranty information or technical support, please refer to the warranty card included in your product packaging or contact Jumper Medical customer service directly. Contact details can typically be found on the manufacturer's official webspletnem mestu ali na embalaži izdelka.
Please have your model number (JPD-FR301) and purchase information ready when contacting support.