1. Uvod
Thank you for choosing the BESTTEN 1U PDU Rack Mount Power Strip. This unit is designed to provide reliable power distribution and surge protection for your electronic equipment, particularly in server racks or similar installations. Please read this manual thoroughly before installation and operation to ensure safe and optimal performance.
2. Varnostna navodila
- Električna varnost: Always connect the PDU to a properly grounded outlet. Do not remove the grounding prong.
- Zaščita pred preobremenitvijo: Do not exceed the maximum electrical rating of 15A/125V/1875W. Overloading can cause damage to the unit and connected devices, and may pose a fire hazard.
- Samo notranja uporaba: This product is intended for indoor use in dry locations. Do not expose to moisture or extreme temperatures.
- Izogibajte se Tampering: Do not attempt to open, modify, or repair the unit. Refer all servicing to qualified personnel.
- Upravljanje kablov: Ensure the power cord is not pinched, walked on, or placed under heavy objects.
- Otroci in hišni ljubljenčki: Hraniti izven dosega otrok in hišnih ljubljenčkov.
3. Vsebina paketa
- BESTTEN 1U PDU Rack Mount Power Strip (Model USM-0U8A-9C)
- Navodila za uporabo
Note: Mounting hardware (screws) may not be included and should be sourced separately if needed for your specific installation.
4. Značilnosti izdelka
- 8 AC vtičnici: Zagotavlja ampnapajalni priključki za več naprav.
- 9-metrski napajalni kabel: Offers flexibility in placement and reach.
- 900 Joulov prenapetostna zaščita: Safeguards connected electronics from power surges and spikes.
- Heavy-Duty Metal Housing: Trpežna konstrukcija za zahtevna okolja.
- 1U Rack Mountable Design: Easily integrates into standard 19-inch server racks.
- Osvetljeno stikalo za vklop: Controls power to all outlets and indicates operational status.
- ETL na seznamu: Certificirano za varnostne in kakovostne standarde.
5. Nastavitev in namestitev
The BESTTEN 1U PDU is designed for versatile installation, including rack mounting or surface mounting.

Figure 1: BESTTEN 1U PDU Rack Mount Power Strip. This image displays the BESTTEN 1U PDU Rack Mount Power Strip. It features a black metal housing with eight standard AC outlets arranged linearly. A red illuminated power switch and a 'SurgePro' indicator are visible at one end. A coiled 9-foot power cord with a standard three-prong plug extends from the unit. Mounting brackets are visible at both ends for rack installation.
5.1 Montaža v stojalo
- Identify an available 1U space in your standard 19-inch server rack.
- Align the mounting brackets on both ends of the PDU with the rack posts.
- Secure the PDU to the rack using appropriate rack screws (not included). Ensure it is firmly attached.
5.2 Surface Mounting (e.g., under desk, wall)
- Choose a flat, stable surface for mounting.
- Use the mounting brackets on the PDU as a template to mark screw locations.
- Po potrebi izvrtajte vodilne luknje.
- Secure the PDU to the surface using appropriate screws (not included). Ensure it is firmly attached and stable.
5.3 Priključitev na napajanje
- Once the PDU is securely mounted, plug its 9-foot power cord into a grounded 125V AC wall outlet.
- The power switch on the PDU should illuminate when power is supplied and the switch is in the 'ON' position.
6. Navodila za uporabo
6.1 Vklop/izklop
- To turn on the PDU and supply power to its outlets, press the red illuminated power switch to the 'ON' position. The switch will light up.
- To turn off the PDU and cut power to all connected devices, press the power switch to the 'OFF' position. The light will extinguish.
6.2 Povezovanje naprav
- Plug your electronic devices into the 8 AC outlets on the PDU.
- Ensure that the total power draw of all connected devices does not exceed the PDU's maximum rating of 1875W (15A at 125V).
6.3 Prenapetostna zaščita
This PDU includes 900 Joules of surge protection to shield your connected equipment from voltage spikes. In the event of a significant power surge, the surge protection feature will activate to absorb the excess energy. If the surge protection is compromised, the 'SurgePro' indicator light (if present and functional) may turn off or change color, indicating that the unit no longer provides surge protection. In such a case, the unit should be replaced.
7. Vzdrževanje
- Čiščenje: Disconnect the PDU from the power source before cleaning. Use a soft, dry cloth to wipe the exterior. Do not use liquid cleaners or aerosols.
- Pregled: Periodically inspect the power cord and the PDU for any signs of damage, such as frayed wires, cracks, or loose connections. If damage is found, discontinue use and replace the unit.
- Outlet Caps: The unit may come with safety caps for unused outlets. Use these to prevent dust accumulation and accidental contact.
8. Odpravljanje težav
| Težava | Možen vzrok | rešitev |
|---|---|---|
| PDU has no power / Power switch light is off. |
|
|
| Priključene naprave ne prejemajo napajanja. |
|
|
| 'SurgePro' indicator light is off. |
|
|
9. Specifikacije
| Funkcija | Podrobnost |
|---|---|
| Številka modela | USM-0U8A-9C |
| Skupna električna vtičnica | 8 |
| voltage Ocena | 125 volta |
| Trenutna ocena | 15 Amps |
| Največja moč | 1875 vatov |
| Prenapetostna zaščita | 900 joulov |
| Dolžina kabla | 9 čevljev |
| Dimenzije izdelka | 19 x 1.75 x 1.75 palcev |
| Teža predmeta | 2.11 funtov |
| Material | Težka kovina |
| Certifikati | ETL na seznamu |
10. Garancija in podpora
BESTTEN products are manufactured to high-quality standards. For specific warranty information, please refer to the warranty card included with your purchase or visit the official BESTTEN website. If you encounter any issues or have questions regarding your BESTTEN 1U PDU, please contact BESTTEN customer support for assistance.