1. Uvod
This manual provides essential instructions for the proper installation, operation, and maintenance of your OHAUS PA4102C Pioneer Precision Balance. To ensure accurate results and prolong the lifespan of your instrument, please read this manual thoroughly before use and keep it for future reference.
The OHAUS PA4102C is a precision laboratory balance designed for accurate weighing applications, featuring a 4100g capacity and internal calibration for reliable performance.
2. Varnostne informacije
- Operate the balance only under the environmental conditions specified in this manual.
- Prepričajte se, da je napajalnik voltage matches the requirements specified on the balance.
- Do not operate the balance in hazardous environments or with unstable power sources.
- Avoid spilling liquids or powders into the balance housing.
- Do not attempt to open or service the balance yourself. Refer all servicing to qualified personnel.
- Always place the balance on a stable, level surface away from vibrations, drafts, and direct heat sources.
3. Izdelek je končanview
The OHAUS PA4102C Pioneer Precision Balance is engineered for reliable and precise weighing. Key features include a clear digital LCD display, a front-mounted bubble level for easy leveling, and selectable environmental settings to adapt to various operating conditions.

An image showing two OHAUS Pioneer precision balances. The balance on the left features a transparent draft shield, typically used for higher precision models. The balance on the right is a simpler model without a draft shield, designed for general weighing tasks. Both balances have a digital LCD display and a stainless steel weighing pan. The PA4102C model is a precision balance with a 4100g capacity and internal calibration.
4. Nastavitev
4.1 Razpakiranje
Previdno vzemite tehtnico in vso dodatno opremo iz embalaže. Embalažo shranite za kasnejši transport ali shranjevanje.
4.2 Namestitev
Place the balance on a firm, stable, and level surface. Ensure the location is free from vibrations, drafts, direct sunlight, and rapid temperature changes. Allow the balance to acclimate to the room temperature for at least 30 minutes before operation.
4.3 Izravnavanje ravnotežja
Adjust the leveling feet located at the base of the balance until the air bubble in the front-mounted level indicator is centered within the circle. This ensures accurate weighing results.
4.4 Napajalni priključek
Connect the supplied AC adapter to the balance and then to a suitable power outlet. The balance may perform a self-test upon initial power-up.
4.5 Začetna kalibracija
The PA4102C features internal calibration. After initial setup and warm-up, it is recommended to perform an internal calibration. Refer to the operating instructions section for details on initiating the internal calibration procedure.
5. Navodila za uporabo
5.1 Vklop/izklop
- Za vklop: Pritisnite [ON/OFF] button. The display will show a self-test sequence and then settle at 0.00g.
- Za izklop: Pritisnite in držite [ON/OFF] gumb, dokler se zaslon ne izklopi.
5.2 Osnovno tehtanje
- Ensure the balance is level and displaying 0.00g.
- Predmet, ki ga želite stehtati, previdno postavite na sredino tehtalne plošče.
- Wait for the stability indicator (usually a star or circle) to appear on the display.
- Read the stable weight value from the digital LCD display.
5.3 Tariranje (ničliranje posode)
- Place an empty container onto the weighing pan.
- Pritisnite [TARA] or [ZERO] button. The display will return to 0.00g.
- V posodo dodajte material, ki ga želite stehtati. Na zaslonu se bo prikazala neto teža materiala.
5.4 Izbira enote
Pritisnite [ENOTA] button (if available) to cycle through available weighing units (e.g., grams, kilograms, milligrams, ounces). The selected unit will be indicated on the display.
5.5 Environmental Settings
The balance allows selection of environmental settings to optimize performance in varying conditions. Consult the on-screen menu or specific button functions to adjust these settings (e.g., for stable, normal, or unstable environments). This helps to compensate for drafts or vibrations.
6. Vzdrževanje
6.1 Čiščenje
Clean the balance regularly using a soft cloth dampened with a mild detergent or water. Do not use abrasive cleaners, solvents, or harsh chemicals. Ensure no liquids enter the balance housing.
6.2 Calibration Checks
Although the PA4102C has internal calibration, it is recommended to periodically verify its accuracy using external calibration weights. If discrepancies are found, perform an internal calibration.
6.3 Shranjevanje
When not in use for extended periods, disconnect the power adapter and store the balance in a clean, dry, and stable environment, ideally in its original packaging.
7. Odpravljanje težav
- Nestabilni odčitki: Check for drafts, vibrations, or temperature fluctuations. Ensure the balance is level. Recalibrate if necessary.
- Display Shows 'Error': Refer to the balance's on-screen error codes (if any) or consult the manufacturer's support. Often, this indicates an overload or internal fault.
- Balance Does Not Turn On: Preverite, ali je napajalnik pravilno priključen in ali vtičnica deluje.
- Netočni odčitki: Ensure the balance is level and has been calibrated recently. Check for debris under the weighing pan.
8. Specifikacije
| Funkcija | Specifikacija |
|---|---|
| Znamka | Ohaus |
| Številka modela | PA4102C (Article No. 001530) |
| Zmogljivost | 4100 g |
| Umerjanje | Notranja kalibracija |
| Zaslon | Digital LCD (without backlight) |
| Niveliranje | Front Bubble Level |
| Nastavitve okolja | Selectable for optimal adaptation |
| Približne dimenzije paketa | 10 x 10 x 10 cm |
| Približna teža paketa | 10 kilogramov |
| Material | Redno |
9. Garancija in podpora
For warranty information, please refer to the warranty card included with your product or contact your authorized OHAUS dealer. Technical support can be obtained by contacting OHAUS customer service directly or through your local distributor. Please have your model number (PA4102C) and serial number ready when requesting support.