Uvod
This manual provides detailed instructions for the installation, operation, and maintenance of your ELKAY 400A Columbus Pneumatic Timer. This device is designed to automatically switch off lighting after a user-defined period, offering a practical solution for energy management.
Pomembne varnostne informacije
WARNING: Risk of electric shock. Installation should only be performed by a qualified electrician or competent person in accordance with national wiring regulations.
- Always disconnect power at the main circuit breaker before installing or servicing the timer.
- Prepričajte se, da so vse žične povezave varne in pravilno izolirane.
- Do not exceed the maximum load ratings specified for this device.
- Ta izdelek je zasnovan samo za uporabo v zaprtih prostorih.
- Hraniti izven dosega otrok.
Konec izdelkaview
The ELKAY 400A Columbus Pneumatic Timer is a single-contact, push-button operated timer. It is designed to replace standard single-gang wall switches and does not require a neutral connection. The timer provides an adjustable delay period, automatically turning off connected lighting after the set time has elapsed.

Slika 1: Spredaj view of the ELKAY 400A Columbus Pneumatic Timer. Shows the white ABS casing and the central push-button mechanism.
Ključne značilnosti:
- Samodejno izklop: Turns off lighting after a set time.
- Nastavljiv časovni zamik: Configurable from approximately 5 seconds to 5 minutes.
- Enostavna namestitev: Replaces existing single-gang wall switches.
- No Neutral Required: Simplifies wiring.
- Združljivost: Suitable for fluorescent (up to 6 fittings) and incandescent lighting.
- Vzdržljiva konstrukcija: Izdelano iz akrilonitril butadien stirena (ABS).
Navodila za namestitev
- Odklop napajanja: Before beginning installation, ensure the electrical supply to the circuit is completely disconnected at the consumer unit/fuse box. Verify with a suitable voltage tester.
- Odstranite obstoječe stikalo: Carefully remove the existing wall switch from its mounting box. Note the wiring connections.
- Ožičenje:
- Connect the incoming live wire to the terminal marked 'L' or 'IN' on the ELKAY 400A timer.
- Connect the switched live wire (going to the light fitting) to the terminal marked 'SW' or 'OUT' on the ELKAY 400A timer.
- Note: This timer does not require a neutral connection.
- Time Delay Adjustment:
The time delay is adjusted via a small screw located on the rear of the timer mechanism. Use a small screwdriver to turn this screw. Turning clockwise typically increases the time, and counter-clockwise decreases it. The timing range is approximately 5 seconds to 5 minutes. Adjust this setting before fully mounting the timer.
Note: Timings are approximate and may require fine-tuning after initial power-up.
- Montaža: Carefully place the wired timer into the wall mounting box, ensuring no wires are pinched. Secure the timer to the box using the provided screws. Attach the faceplate.
- Ponovna priključitev napajanja: Restore power to the circuit at the consumer unit/fuse box.
- Testiranje: Press the timer button to activate. Observe the connected lighting and verify that it switches off after the set delay. Adjust the time delay screw further if necessary (repeat steps 1, 4, 6, 7).
For optimal performance, ensure the mounting surface is flat and does not exert undue pressure on the timer mechanism, which could affect timing accuracy.
Navodila za uporabo
To operate the ELKAY 400A Columbus Pneumatic Timer, simply press the central button. This action will switch on the connected lighting and simultaneously activate the internal pneumatic delay mechanism. The lighting will remain on for the pre-set duration (between 5 seconds and 5 minutes) and then automatically switch off.
- A single press activates the timer.
- The timer cannot be manually turned off before the delay period expires.
- Pressing the button again during an active cycle will restart the timer, extending the light-on period.
Vzdrževanje
The ELKAY 400A Pneumatic Timer requires minimal maintenance. To ensure longevity and proper function:
- Čiščenje: Wipe the surface with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure power is off before cleaning.
- Pregled: Občasno preverjajte morebitne znake poškodb ali ohlapnih priključkov. Če odkrijete kakršne koli težave, izključite napajanje in se posvetujte z usposobljenim električarjem.
- Brez delov, ki bi jih lahko servisiral uporabnik: Do not attempt to open or repair the internal mechanism of the timer. This will void any warranty and could lead to electric shock.
Odpravljanje težav
| Težava | Možen vzrok | rešitev |
|---|---|---|
| Timer does not activate lights. |
|
|
| Lights do not turn off, or turn off too quickly/slowly. |
|
|
| Inconsistent timing. |
|
|
Specifikacije izdelka
- Model: 400A
- Znamka: Elkay
- Material: Akrilonitril butadien stiren (ABS)
- barva: Bela
- Dimenzije izdelka (G x Š x V): 2.17" x 3.35" x 3.35" (približno 55 mm x 85 mm x 85 mm)
- Teža artikla: 3.87 unče (približno 110 g)
- Časovni zamik: Approximately 5 seconds to 5 minutes (adjustable)
- Vrsta stikala: Single Contact, Pneumatic
- Neutral Requirement: Nevtralno ni potrebno
- Združljivost osvetlitve:
- Razsvetljava z žarilno nitko
- Fluorescent lighting (maximum 6 fittings)
- Certifikati: CE, IEC 60669-2-1:2002, RoHS compliant
- Vključene komponente: 1 x Columbus Pneumatic Timer - Single Contact - 400A
Garancija in podpora strankam
For warranty information or technical assistance, please contact Elkay customer support. Keep your purchase receipt as proof of purchase.
Podpora strankam Elkay: Please refer to the official Elkay webkontaktne podatke najdete na spletnem mestu ali embalaži izdelka.