1. Uvod
The Intermatic T101P ON/Off T100 Series Mechanical Timer Switch is a dependable device designed to control electrical loads up to 40 Amperes. It allows for scheduled ON/OFF operations over a 24-hour period, offering convenience and energy management for various applications. This manual provides essential information for the safe installation, operation, and maintenance of your timer switch.
2. Varnostne informacije
Please read and understand all instructions before installing or operating this device. Failure to follow these instructions may result in electrical shock, fire, or serious injury.
- OPOZORILO: Disconnect power at the main circuit breaker or fuse box before installing or servicing the timer switch.
- Namestitev mora opraviti usposobljen električar v skladu z vsemi nacionalnimi in lokalnimi električnimi predpisi.
- Do not connect aluminum wires directly to the switch terminals. Use appropriate copper-to-aluminum connectors if necessary.
- Ensure the timer switch is installed in a suitable NEMA 3R enclosure for outdoor or damp lokacije.
- Preverite, ali voltage and current ratings of the timer switch match your application requirements.
3. Vsebina paketa
Pred začetkom namestitve preverite, ali so prisotne vse komponente:
- Intermatic T101P Mechanical Timer Switch
- Navodila za uporabo (ta dokument)
- Mounting hardware (if included with specific packaging)
4. Značilnosti izdelka
- 24-urno delovanje: Provides up to 12 ON/OFF operations per day.
- Visoka zmogljivost: Handles electrical loads up to 40 Amperes per pole.
- Ročna preglasitev: Features a convenient manual lever for temporary ON/OFF control without affecting programmed settings.
- Trpežno ohišje: NEMA 3R rated plastic enclosure suitable for indoor and outdoor use.
- Vsestranske aplikacije: Ideal for lighting, signs, filters, electric fences, fans, conveyors, pool heaters, blowers, and pumps.
5. Namestitev
Follow these steps for proper installation of the Intermatic T101P timer switch:
- Odklop napajanja: Turn OFF power at the main service panel before beginning any wiring. Ensure the circuit is de-energized using a voltage tester.
- Montaža: Select a suitable location for the timer switch. Mount the enclosure securely using appropriate screws and anchors.
- Ožičenje: Refer to the wiring diagram inside the timer switch enclosure and the image below. Connect the incoming power (LINE) and outgoing load (LOAD) wires to the designated terminals.

Slika 1: Notranji view of the Intermatic T101P timer switch, showing the dial, manual lever, and wiring terminals. Note the 'OFF' and 'ON' positions for the manual lever, and the 'LINE' and 'LOAD' connections.
- Pomembne opombe o ožičenju:
- Observe the warning: DO NOT REMOVE THIS INSULATOR. This component is crucial for safety and proper operation. Wire, lift, and swing the insulator as needed, then replace it after wiring.
- DO NOT CONNECT ALUMINUM WIRES TO SWITCH TERMINALS. Use only copper conductors or approved copper-to-aluminum connectors.
- Zapri prilogo: Once wiring is complete and verified, securely close the timer switch enclosure.
- Obnovi moč: Restore power at the main service panel.
6. Delovanje
The T101P timer switch features a 24-hour dial for setting automatic ON/OFF times and a manual override lever.

Slika 2: Notranji view of the Intermatic T101P timer switch, showing the yellow dial and the protective insulator covering the wiring terminals.
6.1 Setting Automatic ON/OFF Times
- Nastavi trenutni čas: Rotate the yellow dial clockwise until the current time of day aligns with the time arrow indicator.
- Install ON/OFF Trippers: The timer comes with ON (green) and OFF (red) trippers. Slide these trippers onto the dial at the desired ON and OFF times. Ensure they are securely fastened. The minimum ON/OFF time is 1 hour.
- Preverite delovanje: The timer will now automatically turn the connected device ON and OFF according to the set schedule.
6.2 Using the Manual Override Lever
The manual override lever allows you to temporarily switch the connected device ON or OFF without disturbing the programmed schedule.
- To manually turn the device ON, push the lever to the 'ON' position.
- To manually turn the device OFF, push the lever to the 'OFF' position.
- Časovnik bo nadaljeval s programiranim urnikom ob naslednjem načrtovanem dogodku VKLOP ali IZKLOP.
7. Vzdrževanje
The Intermatic T101P is designed for minimal maintenance. Periodically inspect the unit for any signs of damage or loose connections. Ensure the enclosure is free from debris and moisture. No user-serviceable parts are inside; refer servicing to qualified personnel.
8. Odpravljanje težav
| Težava | Možen vzrok | rešitev |
|---|---|---|
| Časovnik ne deluje. | No power to the unit. Incorrect wiring. | Check circuit breaker/fuse. Verify wiring connections are secure and correct. |
| Naprava se ne vklopi/izklopi ob programiranih časih. | Trippers incorrectly set. Current time not set correctly. Manual override engaged. | Ensure trippers are firmly in place at desired times. Adjust the dial to the correct current time. Check if the manual override lever is in the neutral position. |
| Timer makes unusual noise. | Notranja mehanska težava. | Disconnect power immediately. Contact a qualified electrician or Intermatic customer support. Do not attempt to repair. |
9. Specifikacije
| Specifikacija | Vrednost |
|---|---|
| Vrsta | 24 Hour Mechanical Timer |
| Maximum Number of Operations | 12 na dan |
| Minimalni čas vklopa/izklopa | 1 ura |
| Tip stikala | SPST (Enopolni enojni met) |
| Current Rating (Resistive/Inductive/Tungsten) | 40 Amp |
| Current Rating (Ballast) | 16 Amp pri 277 voltih AC |
| Current Rating (Motor, Full Load) | 24 Amp at 120 Volt AC, 28 Amp pri 240 voltih AC |
| voltage Ocena | 120 Volt AC at 60 Hertz |
| Power Rating (Motor) | 2 HP at 120 Volt AC, 5 HP at 240 Volt AC |
| Power Rating (Pilot Duty) | 1000 volt Amp |
| Power Rating (Input) | 3 vatov |
| Delovna temperatura | -40 to 130 Deg F |
| Ohišje | NEMA 3R |
| Material | Plastika |
| Dimenzije (Š x G x V) | 6.5 palcev x 4 palcev x 10 palcev |
| barva | Bež |
| Teža predmeta | 1.29 funta |
| Odobritve | UL (Kanada in ZDA), CSA (Kanada in ZDA) |
10. Garancija in podpora
For warranty information or technical support, please refer to the official Intermatic webspletno mesto ali se obrnite na njihovo službo za pomoč strankam. Shranite račun kot dokazilo o nakupu.