1. Uvod
This instruction manual provides essential information for the safe and effective installation, operation, and maintenance of the MARS 61481 780 Definite Purpose Contactor. Please read this manual thoroughly before attempting any installation or operation to ensure proper function and safety.
2. Izdelek je končanview
The MARS 61481 780 is a 3-pole, 75 Amp definite purpose contactor designed for switching electrical loads in various applications. It features a 120VAC coil for control circuit operation and box lug terminals for secure wiring connections.

Image of the MARS 61481 780 Definite Purpose Contactor, showing its three main power terminals with box lug connections and the two smaller coil terminals at the bottom. The product label is visible on top.
3. Specifikacije
| Znamka | MARS |
| Številka modela | 61481 |
| Trenutna ocena | 75 Amps |
| Število polov | 3 |
| Coil Voltage | 120VAC |
| Vrsta namestitve | Površinska montaža |
| Dimenzije (D x Š x V) | 6 x 5.04 x 3.96 palcev |
| Teža predmeta | 4 funtov |
| UPC | 685744614814 |
4. Varnostne informacije
OPOZORILO: Nevarnost električnega udara. Pred servisiranjem odklopite napajanje.
- Namestitev in servisiranje mora izvajati samo usposobljeno osebje.
- Zagotovite, da upoštevate vse lokalne in nacionalne električne predpise.
- Preverite, ali je dobava voltage se ujema z volumnom tuljave kontaktorjatage (120VAC).
- Kontaktorja ne uporabljajte, če je videti poškodovan.
- Pri delu z električnimi sistemi nosite ustrezno osebno zaščitno opremo (OZO).
5. Namestitev in nastavitev
- Odklop napajanja: Ensure all power to the circuit is disconnected at the main breaker or fuse panel before beginning installation. Verify with a voltage tester.
- Montaža: Securely mount the contactor to a stable surface using appropriate fasteners. The surface mount design allows for direct attachment.
- Wiring Power Terminals: Connect the main power lines to the three large box lug terminals. Ensure proper phase sequence if applicable. Tighten all connections to the manufacturer's specified torque to prevent loose connections and overheating.
- Wiring Coil Terminals: Connect the 120VAC control circuit wires to the smaller coil terminals. These terminals energize the coil, which in turn closes the main contacts.
- Preverjanje: Double-check all wiring connections for correctness and tightness. Ensure no bare wires are exposed.
- Obnovitev napajanja: Ko je namestitev končana in preverjena, ponovno vzpostavite napajanje tokokroga.
Note: Consult a licensed electrician if you are unsure about any part of the installation process.
6. Delovanje
The MARS 61481 780 Definite Purpose Contactor operates by using an electromagnetic coil to open and close a set of electrical contacts. When 120VAC is applied to the coil terminals, the coil energizes, creating a magnetic field that pulls the armature, closing the main power contacts. This allows current to flow through the connected load. When power is removed from the coil, the magnetic field collapses, and springs return the contacts to their open position, interrupting the power to the load.
- Napajanje tuljave: Apply 120VAC to the coil terminals to close the main contacts.
- Izklop tuljave: Remove 120VAC from the coil terminals to open the main contacts.
7. Vzdrževanje
Regular maintenance helps ensure the longevity and reliable operation of your contactor. Always disconnect power before performing any maintenance.
- Vizualni pregled: Periodically inspect the contactor for signs of wear, damage, or discoloration (indicating overheating). Check for loose connections.
- Čiščenje: Keep the contactor free from dust, dirt, and debris. Use a dry, non-conductive brush or compressed air for cleaning. Do not use liquids.
- Tesnost terminala: Re-check the tightness of all terminal connections annually to prevent arcing and overheating.
8. Odpravljanje težav
Če kontaktor ne deluje po pričakovanjih, upoštevajte naslednje pogoste težave:
- Contactor Does Not Engage:
- Check if 120VAC is present at the coil terminals when the control circuit is active.
- Verify the coil is not open or shorted (requires multimeter testing by qualified personnel).
- Ensure mechanical parts are not obstructed.
- Contactor Overheats:
- Check for loose power connections at the terminals.
- Ensure the load current does not exceed the 75 Amp ocena.
- Verify proper ventilation around the contactor.
- Contacts Are Pitted or Welded:
- This indicates excessive arcing or overload. The contactor may need replacement.
- Investigate the cause of overload or frequent switching.
For complex issues, contact a qualified electrician or MARS technical support.
9. Garancija in podpora
For warranty information, please refer to the documentation provided at the time of purchase or contact your authorized MARS distributor. Technical support for products purchased from authorized distributors may be available directly from the distributor.
For general inquiries or to locate an authorized distributor, please visit the official MARS webmesto.