EYE JCR12V100W10H/G1/IR

EYE JCR12V100W10H/G1/IR Dikroični infrardeči Lamp Uporabniški priročnik

Model: JCR12V100W10H/G1/IR

Blagovna znamka: EYE

1. Uvod

This manual provides essential information for the safe and effective use of the EYE JCR12V100W10H/G1/IR Dichroic Infrared Lamp. This high-quality halogen bulb is designed for various professional applications requiring precise illumination and infrared output, including medical, scientific, industrial, and photographic equipment.

Important Note: Please ensure you have the correct model. This lamp is the JCR12V100W10H/G1/IR (Infrared Dichroic) version. Do not confuse it with the JCR12V100W10H/G1/AL (Aluminum Reflector) version, as their optical properties and applications differ significantly.

EYE JCR12V100W10H/G1/IR Dikroični infrardeči Lamp v svoji embalaži.

Figure 1: EYE JCR12V100W10H/G1/IR Dichroic Infrared Lamp v svoji embalaži.

2. Specifikacije

2.1 Splošne specifikacije

  • Model: JCR12V100W10H/G1/IR
  • Tip: Dichroic Infrared Halogen Lamp
  • voltage: 12 V
  • Wattage: 100 W
  • Lamp Osnova: GZ6.35
  • Ocenjena življenjska doba: Približno 1000 ur
  • Izvor: Izdelano na Japonskem

2.2 Fizične lastnosti

Od blizu view of the EYE JCR12V100W10H/G1/IR lamp showing its GZ6.35 pins and dichroic coating.

Figure 2: Close-up of the JCR12V100W10H/G1/IR lamp with GZ6.35 pins.

2.3 Compatible Lamp Holders (Exampmanj)

Table detailing compatible AMP Holders and OEM Kit specifications for Halogen Super White lamps, including voltage, vattage, base, and life hours.

Slika 3: Npramples of compatible AMP Holders and OEM Kit specifications.

Lamp is compatible with GZ6.35 lamp holders. Examples of compatible AMP Holders include (but are not limited to) models such as BJB, VS32400, VS32700, B+W 901, C18A003, B+W 913, B+W 830, OEW-1, and OEW-0, with corresponding G4, G4-G6.35, GX5.3, GZ6.35, and GY9.5 sizes/bases.

2.4 Application-Specific Specifications

Table presenting specifications for lamps used in AOI, PCB industry, photography, and enlarging applications, listing ANSI codes, voltage, vattage, base, life, and application.

Figure 4: Specifications for AOI, PCB, Photo, and Enlarge Lamps.

The JCR12V100W10H/G1/IR lamp is suitable for various applications. For instance, in AOI (Automated Optical Inspection) and PCB (Printed Circuit Board) industries, similar 12V 100W lamps with 50h life are used. In photography and enlarging, lamps with various ANSI codes, voltages (e.g., 36V, 230V, 12V, 24V, 120V, 150V), wattages (e.g., 300W, 100W, 150W, 36W, 55W, 120W, 150W), bases (e.g., GX6.35, GZ6.35, G22, GZ4), and life hours (e.g., 25h, 15h, 20h, 50h, 8000h, 4000h) are common.

Table outlining specifications for medical operation room lamps and dental lamps, including ANSI codes, voltage, vattage, base, life, lumen, and specific medical applications.

Figure 5: Specifications for Medical Operation Room and Dental Lamps.

In medical and dental fields, lamps with similar characteristics are utilized. For example, medical operation room lamps can have ANSI codes like 13938, JM, 6424V, 64F42, BLUF 64F42, 567901947, CZ, with voltages ranging from 22.8V to 24V, wattages from 40W to 150W, and bases like GX5.3, G4, G6.35. Dental lamps, including models like JCR/M10V52W, JCR12V75W, JCR/M12V100W, JCR/M14V36W, feature voltages from 10V to 14V, wattages from 36W to 100W, and GZ4/G6.35 bases, often used for curing applications.

3. Nastavitev in namestitev

3.1 Varnostni ukrepi

  • Always disconnect power to the fixture before installing or replacing the lamp.
  • Allow the old lamp pred ravnanjem popolnoma ohladite, da preprečite opekline.
  • Avoid touching the glass envelope of the new lamp with bare hands. Oils from your skin can create hot spots, reducing lamp life. Use a clean, lint-free cloth or gloves.
  • Zagotovite lamp is securely seated in the lamp nosilec.
  • Preverite, ali voltage in kajtage od lamp match the requirements of your fixture.

3.2 koraki namestitve

  1. Turn off the power supply to the lighting fixture and allow it to cool down.
  2. Previdno odstranite staro lamp from its GZ6.35 socket.
  3. Holding the new EYE JCR12V100W10H/G1/IR lamp with a clean cloth or gloves, align its two pins with the holes in the GZ6.35 lamp nosilec.
  4. Nežno potisnite lamp into the socket until it is firmly seated. Do not force it.
  5. Ko je lamp is installed, restore power to the fixture.
  6. Preizkusite lamp da zagotovite pravilno delovanje.

4. Delovanje

The EYE JCR12V100W10H/G1/IR lamp operates by converting electrical energy into light and infrared radiation. Once properly installed and powered, the lamp will illuminate and emit its characteristic infrared spectrum. This lamp is commonly used in:

  • Medicinska oprema: Such as operating room lights and dental curing lights.
  • Scientific Instruments: For microscopy, endoscopy, and other analytical applications.
  • Industrijske aplikacije: Including Automated Optical Inspection (AOI) and PCB manufacturing.
  • Photography and Projection: For specialized lighting and enlarging equipment.

Ensure that the equipment housing the lamp has adequate ventilation to dissipate heat generated during operation, as halogen lamps can reach high temperatures.

5. Vzdrževanje

5.1 Čiščenje

Če je lamp's glass envelope becomes dirty or smudged, turn off the power and allow the lamp to cool completely. Gently wipe the glass with a clean, lint-free cloth moistened with isopropyl alcohol. Ensure the lamp is completely dry before re-applying power.

5.2 Zamenjava

Lamp has a rated life of approximately 1000 hours. When the lamp reaches the end of its life or fails, follow the installation steps in Section 3.2 to replace it. Always dispose of old lamps according to local regulations for electronic waste.

6. Odpravljanje težav

TežavaMožen vzrokrešitev
Lamp ne zasvetiBrez napajanja za napeljavo
Lamp not seated correctly
Lamp has reached end of life
Faulty fixture/socket
Check power supply and switch
Ponovno namestite lamp trdno
Zamenjajte lamp
Inspect fixture wiring and socket
Reduced brightness or flickeringLamp bliža se koncu življenja
Nepravilna voltage oskrba
Umazan lamp površino
Zrahljana povezava
Zamenjajte lamp
Preverite napajalno voltage
Očistite lamp surface (see 5.1)
Preverite lamp seating and fixture connections
Lamp burns out quicklyNad-zvtage
Pogosto vklop/izklop kolesarjenja
Touching glass with bare hands
Slabo prezračevanje
Poskrbite za pravilno glasnosttage oskrba
Minimize frequent switching
Ročaj lamp with gloves/cloth
Zagotovite zadosten pretok zraka okoli lamp

7. Uporabniški nasveti

  • Ravnajte previdno: Halogenska lamps are delicate. Always handle them by the base or with a clean cloth/gloves to avoid damage and contamination.
  • Preverite združljivost: Before purchase and installation, double-check that the lamp's voltage, vattage, and base type (GZ6.35) are compatible with your specific equipment.
  • Pravilno odstranjevanje: Pri zamenjavi lamp, dispose of the old bulb responsibly according to local environmental regulations.
  • Avoid Over-Voltage: Delovanje lamp pri voltage higher than its rated 12V can significantly shorten its lifespan.

8. Garancija in podpora

For any questions regarding the EYE JCR12V100W10H/G1/IR lamp, including technical support or warranty inquiries, please contact your original point of purchase or the manufacturer's authorized distributor. Keep your purchase receipt as proof of purchase.

Povezani dokumenti - JCR12V100W10H/G1/IR

Prejview Uporabniški priročnik za vmesnik Thermo Scientific TGA s programsko opremo OMNIC Paradigm
Obsežen uporabniški priročnik za vmesnik Thermo Scientific TGA, ki podrobno opisuje njegovo integracijo s programsko opremo OMNIC Paradigm za napredne poskuse deformulacije TGA-IR. Zajema nastavitev, delovanje, vzdrževanje in odpravljanje težav za laboratorijske strokovnjake, ki uporabljajo spektrometre Nicolet FTIR in peči TGA.
Prejview Gleesfun G1 Galaxy Projector User Manual
User manual for the Gleesfun G1 Galaxy Projector, detailing installation instructions, host button operations, remote control functions, and safety precautions for optimal use.
Prejview Product Manual: 36 IR Infrared Lamp
User manual and safety information for the 36 IR infrared lamp, detailing product specifications, compliance, and operating instructions for security camera systems.
Prejview RCN-1 IR Control Lamp DIY Kit - Assembly and Operation Guide
Comprehensive guide for the RCN-1 IR Control Lamp DIY Kit, detailing components, assembly steps, and functionality for creating a white LED night light with infrared remote control and dual brightness.
Prejview Οδηγίες Χειρισμού HYPERCUBE IR30: Ανιχνευτής Φασματοσκοπίας IR & Σαρωτής Βαθιάς Εικόνας 3D
Το HYPERCUBE IR30 είναι ένας προηγμένος ανιχνευτής φασματοσκοπίας υπερύθρου και σαρωτής βαθιάς εικόνας 3D, σχεδιασμένος για την ανάλυση του υπεδάφους, την ανίχνευση μετάλλων και την παροχή λεπτομερών τρισδιάστατων απεικονίσεων. Αυτό το εγχειρίδιο παρέχει λεπτομερείς οδηγίες για τη λειτουργία, τη ρύθμιση και τη βέλτιστη χρήση της συσκευής.
Prejview RCN-1 IR Control Lamp DIY Kit - Assembly Guide
Detailed assembly instructions and component list for the RCN-1 IR Control Lamp DIY Kit. Learn how to build your own infrared-controlled LED lamp.