OLTEANP UPS-TK1500W

OLTEANP 1500W Sump Pump Battery Backup System User Manual

Model: UPS-TK1500W

Blagovna znamka: OLTEANP

1. Uvod

The OLTEANP 1500W Sump Pump Battery Backup System is designed to provide continuous power to your sump pump during power outages, protecting your basement from flooding. This pure sine wave power inverter with a built-in charger automatically switches between grid power and battery power, ensuring reliable operation. It features an LCD screen remote controller for easy monitoring and multiple safety protections.

2. Varnostne informacije

Pred namestitvijo in uporabo natančno preberite vsa varnostna navodila. Neupoštevanje teh navodil lahko povzroči električni udar, požar ali resne poškodbe.

  • Poskrbite za ustrezno prezračevanje okoli enote, da preprečite pregrevanje.
  • Do not expose the unit to water, rain, snow, or spray.
  • Connect the unit only to a 12V battery system.
  • Ensure all connections are tight and secure to prevent arcing.
  • Ne razstavljajte enote. Vsa servisna dela prepustite usposobljenemu osebju.
  • Keep away from flammable materials and gases.
  • Always wear appropriate personal protective equipment (PPE) when handling batteries and electrical connections.

3. Vsebina paketa

Preverite, ali so v paketu prisotni vsi elementi:

  • 1500W Sump Pump Battery Backup System (Main Unit)
  • Battery Cables (Red and Black)
  • Uporabniški priročnik (ta dokument)
  • Remote Controller with LCD Screen
  • Napajalni kabel
  • Accessories (e.g., wrench, earth wire)
OLTEANP 1500W Sump Pump Battery Backup System and included accessories

Image: The main unit of the OLTEANP 1500W Sump Pump Battery Backup System along with its remote controller, battery cables, and power cable.

4. Izdelek je končanview

The OLTEANP 1500W system integrates an inverter, charger, and automatic transfer switch into one compact unit. Key features include:

  • Čisti sinusni izhod: Zagotavlja čisto in stabilno napajanje, primerno za občutljivo elektroniko.
  • Built-in 25A Battery Charger: Supports fast charging for various deep-cycle battery types (Lithium, AGM, Flooded/Wet).
  • Samodejno preklapljanje: Seamlessly transitions from grid power to battery power (and vice-versa) within 12ms during outages.
  • Več izhodov: Features 3 AC outlets, a 36W Type-C port, and a 5V/3.1A USB port.
  • LCD Remote Controller: Displays real-time battery status, AC output, and fault indicators.
  • Večnamenska varnostna zaščita: Includes overheat, short circuit, low voltage, overcharge, high voltage, overload, and earth wire protection.
Remote controller with LCD screen displaying battery and power status

Image: Close-up of the remote controller's LCD screen, showing battery charge, DC input voltage, izhodna voltage in kajtage. Fault indicators for overheat, overload, and short circuit are also visible.

Diagram of multi-functional safety protections

Image: Icons representing the multi-functional safety protections: High-Voltage Protection, Overload Protection, High-Temperature Protection, Smart IC, Low Voltage Protection, and Short-Circuit Protection.

Podrobno view of the inverter's AC and DC side ports and features

Image: A detailed diagram labeling the various ports and features on the inverter, including USB Port, Fault LED, Power LED, Fully Charged Indicator, Battery Type Selection Button, ON/OFF switch, L, N, PE terminals, Earth wire, Remote Connection port, Negative Terminal, Cooling Fan, Positive Terminal, 120V AC Outputs (x3), Type-C Port, AC Fuse, and AC Charge Input.

5. Nastavitev

The OLTEANP sump pump battery backup system is designed for easy installation with minimal wiring required.

5.1 Izbira lokacije

  • Select a dry, well-ventilated area, away from direct sunlight, heat sources, and flammable materials.
  • Ensure sufficient space around the unit for proper airflow and cooling.
  • The unit can be placed flat or wall-mounted using the fixed holes on the side.

5.2 Priključitev baterije

A 12V deep-cycle battery (not included) is required for operation. Ensure the battery is compatible with the system (Lithium, AGM, Flooded/Wet).

  1. Connect the red battery cable to the positive (+) terminal of the battery and the positive (+) terminal on the inverter.
  2. Connect the black battery cable to the negative (-) terminal of the battery and the negative (-) terminal on the inverter.
  3. Prepričajte se, da so vse povezave tesne in varne.

5.3 Vhodni in izhodni priključki za izmenični tok

  1. Plug the provided AC power cable into the "AC Charge Input" port on the inverter and then into a standard wall outlet.
  2. Connect your sump pump(s) and other desired appliances (within the 1500W limit) to the 3 AC output sockets on the inverter.
  3. For additional charging, use the USB and Type-C ports as needed.
Diagram showing the inverter connected to a battery and a sump pump system

Image: A schematic illustrating the connection of the OLTEANP inverter to a 12V battery and a sump pump. It shows the AC charge input, 3 AC outlets, USB port, and Type-C port, with power flow indicated for charging the battery and powering the sump pump.

5.4 Priključitev daljinskega upravljalnika

  • Connect the remote controller cable to the "Remote Connection" port on the inverter. This allows for convenient monitoring and control from a distance.

5.5 Izbira tipa baterije

Before turning on the inverter, select the correct battery type using the switches on the unit. Refer to the table below for settings:

Table for selectable battery types and corresponding switch settings

Image: A table showing the switch settings (1 and 2, ON/OFF) for different battery types (GEL, AGM/SLA, Flooded/Wet, LiFePO4) along with their Bulk/Absorption and Float voltage nastavitve.

Battery Type Selection Settings
Stikalo 1Stikalo 2Vrsta baterijeBulk/Absorpcija VoltageFloat Voltage
IZKLOPIZKLOPGEL14.2 V13.6 V
IZKLOPONAGM/SLA14.4 V13.6 V
ONIZKLOPFlooded/Wet14.7 V13.6 V
ONONLiFePO414.6 V14.6 V

6. Navodila za uporabo

6.1 Začetni vklop

  1. After all connections are made and the battery type is selected, turn on the main power switch on the inverter.
  2. The Power LED (Green) should illuminate.
  3. The LCD remote controller will display current battery voltage, AC output, and wattage.

6.2 Normal Operation (Grid Power Available)

When grid power is available, the system operates in charging mode:

  • The connected sump pump(s) and other devices will be powered directly by the grid.
  • The built-in 25A charger will automatically charge the connected 12V battery. The "Fully Charged Indicator" will show the charging status.
  • The LCD remote controller will show the charging status and battery voltage.

6.3 Power Outage Operation (Battery Backup)

V primeru izpada električne energijetage, the system automatically switches to battery power:

  • The system will detect the loss of grid power and instantly switch to inverter mode within 12ms.
  • The sump pump(s) and other connected devices will continue to operate, powered by the battery through the inverter.
  • The LCD remote controller will display the battery voltage and the power being drawn by the connected loads.
  • When grid power is restored, the system will automatically switch back to grid power and resume charging the battery.
Image showing the inverter powering multiple sump pumps

Image: A visual representation of the OLTEANP 1500W system connected to and powering three sump pumps simultaneously, demonstrating its capacity to handle multiple loads up to 1500 watts.

6.4 Using USB and Type-C Ports

The USB (5V/3.1A) and Type-C (36W) ports can be used to charge compatible electronic devices during both grid and battery operation.

7. Vzdrževanje

Regular maintenance ensures the longevity and optimal performance of your OLTEANP Sump Pump Battery Backup System.

  • Čistoča: Napravo vzdržujte čisto in brez prahu ter umazanije. Za čiščenje uporabljajte suho, mehko krpo. Ne uporabljajte tekočih čistil.
  • Prezračevanje: Ensure the cooling fans and vents are not obstructed. Periodically check for dust buildup and clean if necessary.
  • Zdravje baterije: Regularly check the battery terminals for corrosion and ensure connections are tight. For flooded batteries, check electrolyte levels as per battery manufacturer's instructions.
  • Test funkcionalnosti: Periodically test the system by simulating a power outage (e.g., by unplugging the AC input) to ensure it switches to battery power correctly.
  • Shranjevanje: If storing the unit for an extended period, ensure the battery is fully charged and disconnect it from the inverter. Store in a cool, dry place.

8. Odpravljanje težav

This section addresses common issues you might encounter with your OLTEANP Sump Pump Battery Backup System.

TežavaMožen vzrokrešitev
Iz vtičnic za izmenični tok ni izhodne napetosti.
  • Inverter je IZKLOPLJEN.
  • Baterija je prazna ali ni priključena.
  • Aktivirana zaščita pred preobremenitvijo.
  • LED-lučka za napako sveti.
  • AC input power is off.
  • Prepričajte se, da je stikalo za VKLOP/IZKLOP v položaju VKLOP.
  • Check battery connections and charge level.
  • Zmanjšajte obremenitev, priključeno na pretvornik.
  • Check the LCD remote controller for specific fault codes and refer to the manual for resolution.
  • Verify grid power is available and AC input cable is securely plugged in.
Baterija se ne polni.
  • AC input power is off or cable loose.
  • Izbrana je napačna vrsta baterije.
  • Battery cables loose or corroded.
  • Baterija je v okvari.
  • Check AC input power and cable connection.
  • Verify the battery type selection switches are set correctly for your battery.
  • Inspect and tighten battery cable connections. Clean any corrosion.
  • Test the battery with a battery tester. Replace if faulty.
Inverter shuts down frequently.
  • Preobremenitev.
  • Pregrevanje.
  • Nizka voltage.
  • Zmanjšajte skupno vattage povezanih naprav.
  • Ensure proper ventilation; clean cooling fans if necessary.
  • Charge the battery. Ensure battery capacity is sufficient for the load.
Inverter does not turn on automatically after full battery discharge and AC power returns.
  • This is a known operational characteristic after a complete battery drain.
  • After the battery has recharged, manually turn the inverter ON using the main power switch or the remote controller.

9. Specifikacije

FunkcijaPodrobnost
ModelUPS-TK1500W
Neprekinjeno napajanje1500 W
Največja moč3000 W
Vhodna voltage12V DC
Izhodna voltage120 V AC
Izhodna valovna oblikaČisti sinusni val
Tok polnilnika baterije25A
Čas prenosa12ms
AC izhodi3 x 120V AC Outlets
Vrata USB5V/3.1A
Vrata Type-C36 W
Dimenzije (D x Š x V)14.48 x 7.91 x 4.49 palcev (368 x 201 x 114 mm)
Teža predmeta11.75 funtov
MaterialKovina
barvaModra
Dimensions and included accessories of the OLTEANP 1500W Sump Pump Battery Backup System

Image: A diagram illustrating the dimensions of the main inverter unit and showing all included accessories: power cable, remote control, battery cables (red and black), and additional accessories like a wrench.

10. Garancija in podpora

The OLTEANP Sump Pump Battery Backup System comes with a 12 mesecev garancije od datuma nakupa.

For technical support, warranty claims, or any questions regarding your product, please contact OLTEANP customer service through the retailer's platform or the official OLTEANP website. Please have your model number (UPS-TK1500W) and purchase date available when contacting support.

Za več informacij lahko obiščete OLTEANP Store on Amazon.

© 2025 OLTEANP. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.