1. Uvod
The DX-Smart LR02 is a low-power LoRa module designed for wireless data transmission. It integrates an ASR6601 RF chip and supports UART serial communication, enabling transparent data transfer between devices. This module operates within the 433~475MHz frequency range and is suitable for various Internet of Things (IoT) applications requiring long-range and low-power connectivity.
Glavne lastnosti vključujejo:
- ASR6601 SOC Chip with 32-bit ARM STAR Core.
- Maximum Frequency: 48MHz.
- UART Serial Communication with configurable baud rates (1200 to 128000).
- Extensive AT command set for module configuration.
- Support for 410~493MHz frequency range, ensuring global compatibility.
- High power PA with +22dBm output.
- Maximum Receiver Sensitivity: -138dBm.
- Supports sleep mode and wake-on-air mode.
- Line-of-sight distance up to 5km in open areas.
- Delovna zvezatage: 3.3V-5.5V (typical: 5V).
- Module Size: 36(L)x16.5(W)x4(H)mm.
- CE, FCC, RoHS certified.
2. Setup and Hardware Connection
This section details the physical connection of the LR02 module, including pinout and wiring diagrams. Ensure correct polarity when connecting the module to an adapter board or development environment.
2.1 Razporeditev pinov modula
The LR02 module features a standard pinout for easy integration. Refer to the diagram below for pin identification and function.

Slika 2.1: LR02 Module Pinout and Example Wiring Diagram. The diagram illustrates the pin assignments for the LR02 module and a typical connection to an adapter plate, showing connections for M0, M1, PXD, TXD, RXD, AUX, VCC, and GND.
- M0, M1: Rezervirana, prilagodljiva V/I vrata.
- PXD: Not explicitly defined in the diagram, but typically related to data transmission.
- TXD: UART Transmit Data.
- RXD: UART Receive Data.
- AUX: Auxiliary pin (refer to detailed documentation for specific functions).
- VCC: Power Supply (3.3V-5.5V).
- GND: Tla.
2.2 Status indikatorja
The module includes an indicator light to show its operational status:
- Delovni status: Utripa rdeča lučka.
- Način mirovanja: Light off when hibernating, red light flashing when waking up.
3. Načini delovanja in AT ukazi
The LR02 module supports various working modes and is configured using a comprehensive set of AT commands via its UART serial interface. This allows for flexible integration into different applications without requiring custom LoRa programming.
3.1 Supported Working Modes
The module can operate in three primary data transmission modes:

Slika 3.1: Illustration of LR02 Module Working Modes (Transparent, Fixed-Point, Broadcast) and a partial AT Command Set. The diagram visually explains how data is transmitted in each mode and lists common AT commands for configuration.
- Modul in transparenten prenos modulov: Za prenos podatkov je potreben isti kanal tako za pošiljatelja kot za prejemnika.
- Modul in modul s fiksno točko prenosa: Communicates with modules using specified addresses and channels. Data format is hexadecimal: receiving address + receiving channel + data.
- Moduli in prenos oddajanja modulov: Communicates with designated channel modules. Data format is hexadecimal: receiver channel + data.
3.2 Nabor ukazov AT
AT commands are used to configure and query the module's parameters. A serial port testing software can be used for this purpose.

Slika 3.2: Screenshot of a UART Assistant Tools software demonstrating serial port testing and a table of common AT commands. This image shows how to interact with the module using AT commands and a software interface.
Pogosti ukazi AT vključujejo:
- V: Test command (responds with OK).
- +++: Enter/exit AT command mode.
- AT+BAUD: Set/query baud rate.
- AT+NAČIN: Set/query operating mode.
- SPANJE: Set/query power consumption mode.
- NA+KANALU: Set/query working channels.
- AT+MAC: Set/query device address.
- AT+POWE: Set/query transmit power.
- AT+IQ: Setting the IQ signal flip-flop.
For a complete list and detailed usage of AT commands, please consult the product information packages and technical documentation provided by DX-SMART.
4. Vzdrževanje
The DX-Smart LR02 module is designed for robust operation. To ensure its longevity and reliable performance, consider the following general maintenance guidelines:
- Okoljski pogoji: Modul uporabljajte znotraj določenih temperaturnih in vlažnih območij. Izogibajte se izpostavljanju ekstremnim temperaturam, vlagi ali korozivnim okoljem.
- Fizično ravnanje: Handle the module with care to prevent physical damage to components or solder joints. Avoid excessive force when connecting or disconnecting antennas and cables.
- Napajanje: Zagotovite stabilno in čisto napajanje znotraj navedene glasnostitage range (3.3V-5.5V). Unstable power can affect performance and module lifespan.
- Čiščenje: If necessary, gently clean the module with a soft, dry cloth. Avoid using liquids or harsh chemicals.
- Posodobitve vdelane programske opreme: Občasno preverite proizvajalčeve webZa morebitne posodobitve vdelane programske opreme, ki lahko izboljšajo delovanje ali dodajo nove funkcije, obiščite spletno mesto. Za vse postopke posodabljanja natančno upoštevajte priložena navodila.
5. Odpravljanje težav
If you encounter issues with your DX-Smart LR02 module, consider the following troubleshooting steps:
- No Power/Indicator Off:
- Preverite napajalno voltage je med 3.3V in 5.5V.
- Check all power connections for proper contact and polarity.
- Ensure the module is not in hibernation mode (indicator light off).
- Communication Failure (UART):
- Confirm TXD and RXD lines are correctly connected (TX of one device to RX of the other).
- Verify that the baud rate settings on both the module (via AT commands) and the host device match.
- Preverite morebitne ohlapne povezave ali poškodovane žice.
- Ensure the module is not in sleep mode, which would prevent communication.
- Slab brezžični doseg/povezljivost:
- Ensure the antenna is securely connected and appropriate for the operating frequency.
- Check for obstructions between modules (e.g., thick walls, metal objects).
- Preverite, ali sta oba modula konfigurirana na isto frekvenco in kanal.
- Confirm transmit power settings using AT commands.
- Modul se ne odziva na AT ukaze:
- Ensure you are sending the correct AT command prefix (e.g., '+++' to enter command mode).
- Check serial port settings (baud rate, data bits, parity, stop bits).
- Confirm the module is powered on and not in a deep sleep state.
If problems persist after following these steps, please refer to the technical support section for further assistance.
6. Specifikacije
Detailed technical specifications for the DX-Smart LR02 LoRa Module:

Slika 6.1: Visual representation of the LR02 module highlighting key features and physical dimensions (35.6mm length, 18mm width, 2.54mm pin pitch).
| Parameter | Podrobnost |
|---|---|
| Model čipa | ASR6601 |
| Komunikacijski vmesnik | UART serijska vrata |
| Brezžična vrsta | Radio Frequency (LoRa) |
| Frekvenčni pas | 433~475MHz (Supports 410~493MHz) |
| Oddajna moč | +22 dBm |
| Občutljivost sprejemnika | -138dBm |
| Komunikacijska razdalja | Up to 5km (line-of-sight in open areas) |
| Podpora za baud hitrost | 1200, 2400, 9600, 19200, 38400, 57600, 115200, 128000 |
| Delovna zvezatage | 3.3V–5.5V (tipično: 5V) |
| Delovna temperatura | -40°C do +85°C |
| Dimenzije modula (D x Š x V) | 36 mm x 16.5 mm x 4 mm |
| Certifikati | CE, FCC, RoHS |

Slika 6.2: Image illustrating a drone-measured communication distance test, showing the LR02 module achieving a visible range of up to 5km in an open environment. Note: Actual performance may vary based on environmental factors.
7. Informacije o garanciji
Specific warranty terms for the DX-Smart LR02 LoRa Module are typically provided at the point of purchase or within the product packaging. For detailed warranty information, including coverage period and conditions, please refer to the documentation supplied by your seller or contact DX-SMART directly.
8. Tehnična podpora in viri
DX-SMART provides comprehensive technical support and resources to assist with the integration and operation of the LR02 module. These resources include:
- Tehnična dokumentacija: Detailed datasheets, user guides, and application notes.
- AT Command Sets: Full documentation of all available AT commands for advanced configuration.
- Module Footprints and Reference Design Schematics: For hardware integration.
- Development/Test Tools: Software and hardware tools to aid in development and testing.
For further assistance or to access these resources, please contact DX-SMART customer service. You can typically find contact information through the 'User Guide', 'Product Information', or 'Service Support' sections on the manufacturer's official webspletnem mestu ali prek prodajalca izdelka.