The Reznor UDXC series natural gas heaters are designed to provide efficient and reliable heating for a variety of indoor spaces. These units are ideal for commercial, industrial, and residential applications such as garages, workshops, warehouses, and factories. The UDXC-60 model, with its 60,000 BTU output, offers quiet forced air heating, ensuring a comfortable environment while minimizing operational noise.

This manual provides essential information for the safe and effective installation, operation, and maintenance of your Reznor UDXC-60 unit heater. Please read all instructions thoroughly before proceeding with installation or use.

Reznor UDXC-60 Natural Gas Unit Heater

Slika 1: Spredaj view of the Reznor UDXC-60 Natural Gas Unit Heater.

2. Varnostne informacije

OPOZORILO: Ta izdelek vas lahko izpostavi kemikalijam, vključno s svincem in svinčevimi spojinami, za katere je v zvezni državi Kalifornija znano, da povzročajo raka in prirojene okvare ali drugo škodo pri razmnoževanju. Za več informacij pojdite na www.p65warnings.ca.gov.

  • Installation and service must be performed by a qualified installer, service agency, or gas supplier. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death.
  • Ensure adequate ventilation in the installation area to prevent carbon monoxide buildup.
  • Ne shranjujte ali uporabljajte bencina ali drugih vnetljivih hlapov in tekočin v bližini te ali katere koli druge naprave.
  • Keep the area around the heater clear and free from combustible materials.
  • Always follow all local and national codes and regulations for gas appliance installation and operation.

3. Nastavitev in namestitev

The Reznor UDXC-60 unit heater is designed for versatile mounting and venting options. Professional installation is highly recommended to ensure safety and compliance with all applicable codes.

3.1 Montaža

The unit features threaded-nut retainers at four suspension points, allowing for secure installation as a ceiling-mounted hanging furnace or a wall-mounted heater. Mounting brackets are sold separately. Ensure the mounting structure can safely support the weight of the unit.

Reznor UDXC-60 Unit Heater with mounting points

Figure 2: Unit heater showing suspension points and external gas connection.

Mounting bracket for Reznor heater

Slika 3: Nprample of a mounting bracket (sold separately).

3.2 Odzračevanje

Proper venting is crucial for safe operation. The UDXC-60 is compatible with:

  • Category 1 double wall B-vent when venting vertically out of a roof.
  • Category 3 single wall vent pipe when vented horizontally through a sidewall.

Consult the detailed installation instructions provided with the unit for specific venting requirements and clearances.

3.3 Električna povezava

The unit requires a 24V electrical connection, accessible via an external terminal strip. All electrical wiring must comply with local and national electrical codes and be performed by a licensed electrician.

Poenostavljena namestitev in napredne funkcije grelnika Reznor

Slika 4: Konecview of simplified installation features including electrical connections.

4. Navodila za uporabo

The Reznor UDXC-60 is designed for efficient and quiet operation, providing consistent heat for your space.

4.1 stopnje ogrevanja

The UDXC-60 offers two heating output levels to adapt to varying temperature needs:

  • Nizek ogenj: 34,860 BTU, suitable for milder cool days.
  • Močan požar: 49,800 BTU, for the coldest times of the year.

The unit achieves an 83% thermal efficiency rating, ensuring effective heat delivery.

Prilagodljivost ogrevanja grelnika Reznorjev UDXC

Figure 5: Illustration of the heater's heating flexibility with two BTU outputs.

4.2 Quiet Forced Air Heating

UDXC models are engineered for quiet operation, featuring a vibration/noise isolated low static pressure axial propeller fan and a power venting system. This design provides optimal performance in most indoor environments without excessive noise, making them ideal for spaces where sound levels are a concern.

Air Circulation in a garage with Reznor heater

Figure 6: Diagram illustrating efficient air circulation and heat distribution.

Features: Scratch Resistant, Durable Build, Modern Design, Quiet Operation

Figure 7: Key features highlighting quiet operation and durable design.

5. Vzdrževanje

Regular maintenance ensures the longevity and efficient operation of your Reznor UDXC-60 heater. Always disconnect power and gas supply before performing any maintenance.

  • Letni pregled: It is recommended to have a qualified service technician inspect the unit annually, especially before the heating season.
  • Čiščenje: Keep the fan blades and heat exchanger clean from dust and debris. The improved cabinet design with a removable front face and a hinged access door panel with a quarter-turn latch facilitates easier access for cleaning and inspection.
  • Preverjanje prezračevalnega sistema: Periodically inspect the vent system for any obstructions, leaks, or damage.
  • Preverjanje plinske povezave: Ensure all gas connections are secure and free from leaks.

6. Odpravljanje težav

The Reznor UDXC-60 features an integrated circuit board with a 7-segment display and a status-indicating LED for simplified troubleshooting. Refer to the unit's display for error codes and status indicators.

  • Ni ogrevanja/enota se ne zažene:
    • Preverite nastavitev termostata.
    • Verify the gas supply is on.
    • Ensure the power supply is connected and the built-in disconnect switch is engaged.
    • Check the 7-segment display for error codes.
  • Nenavadni zvoki:
    • Inspect the fan for obstructions or damage.
    • Prepričajte se, da je enota varno nameščena in da ni izpostavljena vibracijam.
  • Slaba ogrevalna zmogljivost:
    • Check for proper air circulation and clear any obstructions around the unit.
    • Ensure the correct heating level (low/high fire) is selected for the ambient temperature.

V primeru trajnih ali zapletenih težav se obrnite na usposobljenega serviserja.

7. Specifikacije

FunkcijaPodrobnost
ZnamkaReznor (Distributed by 1HVAC)
Številka modelaUDXC-60
Toplotna moč60,000 BTU (Two levels: Low Fire 34,860 BTU / High Fire 49,800 BTU)
Toplotna učinkovitost83 %
Vrsta gorivaZemeljski plin
Notranja/zunanja uporabaNotranja
Mere izdelka (D x Š x V)32.72 cm x 27 cm x 16.75 cm
Vrsta namestitveCeiling Mount, Wall Mount (using suspension points)
Vrsta sobeGarage, Commercial, Industrial
Posebna funkcijaFast Heating, Quiet Operation, Integrated Circuit Board with Display
Izmenjevalec toploteTCORE2 titanom stabilizirano aluminizirano jeklo
Prvič na voljo14. julij 2023
Dimensions of Reznor UDXC-60 Unit Heater

Figure 8: Key dimensions of the UDXC-60 unit heater.

Standard Features of Reznor Model UDXC-60 Unit Heater

Slika 9: Konecview of standard features including efficiency and heat exchanger material.

8. Informacije o garanciji

The Reznor UDXC-60 unit heater comes with the following warranty coverage:

  • 9 let: Sestav toplotnega izmenjevalnika, gorilnika in zbiralnika dimnih plinov.
  • 4 let: Vse električne in mehanske komponente.

To ensure a valid warranty, installation must comply with all local and state codes. Retain your proof of purchase and installation records for warranty claims.

9. Podpora in stik

For further assistance, technical support, or to purchase accessories and replacement parts, please refer to the contact information provided by your retailer or visit the official Reznor website. Always provide your model number (UDXC-60) when seeking support.

For more information about Reznor's commitment to quality and innovation, you can visit the 1HVAC trgovina na Amazonu.

© 2023 Reznor. Vse pravice pridržane.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.