DEVMO JZ801

DEVMO DC 5V/12V 1 Channel Relay Board (Model JZ801) User Manual

Programmable Multifunctional Module Cycle Timing Circuit Switch

1. Uvod

This manual provides detailed instructions for the DEVMO DC 5V/12V 1 Channel Relay Board, Model JZ801. This programmable multifunctional module is designed for various timing and control applications, offering flexible operation modes and robust performance.

Glavne lastnosti vključujejo:

  • Širok vhodni voltage range: 6-30V, with micro USB 5.0V power supply option.
  • Adjustable timing range: 0.1 seconds to 999 minutes.
  • Visoka glasnosttage level trigger (3.0V-24V).
  • Output capability: DC 0-30V 5A or AC 0-220V 5A.
  • Opto-isolator for enhanced anti-interference.
  • Reverse connect protection.
  • Automatic parameter saving upon power-off.
  • Sleep mode for power saving.

2. Vsebina paketa

Prosimo, preverite, ali so v vašem paketu vsi elementi:

  • 1x DEVMO 1 Channel Multi-functional Time Delay Relay Board (blue board)
  • 1x USB to Micro USB Power Line
DEVMO JZ801 Relay Board with included USB cable

Figure 2.1: DEVMO JZ801 Relay Board and USB to Micro USB Power Line.

This image displays the DEVMO JZ801 1 Channel Relay Board, a blue circuit board with a 3-digit LED display, three control buttons (SET, STOP), a relay, and screw terminals for connections. A blue USB to Micro USB cable is also shown alongside the board.

3. Izdelek je končanview in Povezave

Familiarize yourself with the components and connection points of the relay board.

Vrh view of DEVMO JZ801 Relay Board

Slika 3.1: Zgornji del view of the DEVMO JZ801 Relay Board.

Ta slika ponuja jasen pogled od zgoraj navzdol view of the blue DEVMO JZ801 relay board, highlighting the 3-digit LED display, the three push buttons (SET, STOP, and one unmarked), the relay component, and the screw terminals for power input and relay output.

Spodaj view of DEVMO JZ801 Relay Board showing JZ-801 marking

Slika 3.2: Spodaj view of the DEVMO JZ801 Relay Board.

This image shows the underside of the DEVMO JZ801 relay board, revealing the solder points, circuit traces, and the model number 'JZ-801' printed on the PCB. It also indicates the power input terminals (6.0~30.0V, GND) and trigger input (Trigger, GND_TO).

3.1 Vhodna moč

  • DC vhod: Connect a DC power source between 6V and 30V to the screw terminals labeled 6.0 ~ 30.0 V (pozitivno) in GND (negativno).
  • Mikro USB vhod: Alternatively, power the module using a 5V Micro USB power supply connected to the Micro USB port.

3.2 vnos sprožilca

  • The trigger source requires a high voltage level between 3.0V and 24V.
  • Connect the trigger signal to the terminal labeled Sprožilec and the ground reference to GND_TO.

3.3 relejni izhod

The relay provides three terminals for connecting your load:

  • NE (običajno odprto): This terminal is open (disconnected) when the relay is de-energized and closed (connected to COM) when energized.
  • COM (Skupno): To je skupni priključek za relejno stikalo.
  • NC (normalno zaprto): This terminal is closed (connected to COM) when the relay is de-energized and open (disconnected from COM) when energized.

The relay can control devices within DC 0-30V 5A or AC 0-220V 5A.

4. Navodila za uporabo

4.1 Main Interface and Display

When the module is off, the display shows "000" (no decimal point). During operation, the display will show a decimal point, indicating active status.

DEVMO JZ801 Relay Board showing LED display and buttons

Figure 4.1: DEVMO JZ801 Relay Board with LED display and control buttons.

This image highlights the 3-digit LED display and the three control buttons (SET, STOP, and an unlabeled button) on the DEVMO JZ801 relay board, which are used for programming and operating the module.

4.2 Definicije parametrov

  • OP: Turn-On Time (duration the relay is energized).
  • CL: Turn-Off Time (duration the relay is de-energized).
  • LOP: Cycle Index (number of cycles). "---" indicates an limitless cycle.

These parameters are independent for each work mode but share the same values across different modes once set.

4.3 Nastavitev časa

To set timing values:

  1. Enter the mode selection screen (see Section 4.4).
  2. After setting the parameter values (OP, CL, LOP), short press the STOP button to select the time range for the currently displayed parameter.
  3. Available time ranges:
    • XXX: 1 second to 999 seconds (e.g., 123 for 123 seconds).
    • XX.X: 0.1 seconds to 99.9 seconds (e.g., 12.3 for 12.3 seconds).
    • X.X.X.: 1 minute to 999 minutes (e.g., 1.2.3. for 123 minutes).

4.4 Work Mode Selection

Dolgo pritisnite NASTAVI key to enter or exit the mode selection screen. In this screen, you can choose different operational modes for the relay.

4.5 Relay Enable/Disable Mode

From the main interface, a short press of the STOP button will toggle the relay between ON and OFF states, effectively enabling or disabling its operation.

4.6 Način mirovanja

To activate or deactivate sleep mode:

  1. Dolgo pritisnite STOP za dve sekundi.
  2. Release the button to switch between Cl (normal mode) and O-d (sleep mode) states.

In sleep mode, if there is no operation for five minutes, the digital display automatically turns off to save power. Press any key to turn the display back on.

5. Vzdrževanje

  • Modul naj bo čist in brez prahu ter vlage.
  • Izogibajte se izpostavljanju modula ekstremnim temperaturam ali neposredni sončni svetlobi.
  • Prepričajte se, da so vse povezave varne, da preprečite prekinitveno delovanje.
  • Do not attempt to modify the circuit board, as this may void any warranty and cause damage.

6. Odpravljanje težav

  • Modul se ne vklopi: Preverite napajalno voltage is within the 6-30V range for DC input, or ensure the Micro USB cable is properly connected to a 5V source. Check for correct polarity on DC input.
  • Relay not triggering: Ensure the trigger signal voltage is between 3.0V and 24V. Check the trigger input connections for proper contact. Verify the selected work mode and timing parameters are correctly configured.
  • Napačen čas: Double-check the OP, CL, and LOP parameter settings. Ensure the correct time range (seconds, 0.1 seconds, minutes) is selected for each parameter.
  • Zaslon je izklopljen: The module might be in sleep mode. Press any button to reactivate the display. If not in sleep mode, check power supply.
  • Občasno delovanje: Check all wiring connections for looseness. Ensure the load current does not exceed the relay's maximum rating (DC 0-30V 5A or AC 0-220V 5A). The built-in opto-isolator helps reduce interference, but ensure your environment is free from excessive electrical noise.

7. Specifikacije

Funkcija Specifikacija
Številka modela JZ801
Dimenzije (D x Š x V) 6.2 cm x 3.8 cm x 1.7 cm (2.44 x 1.50 x 0.67 palcev)
Delo Voltage DC 6-30V (supports Micro USB 5.0V power supply)
Vir sprožilca Visoka glasnosttage level trigger (3.0V-24V)
Izhodna zmogljivost DC 0-30V 5A or AC 0-220V 5A
Mirujoči tok 20mA
Delovni tok 50mA
Življenjska doba Več kot 100,000-krat
Delovna temperatura -40°C do +85°C
Časovni razpon 0.1 sekunde do 999 minut (nastavljivo)
Teža 0.06 kilograma (približno 2.08 unče)

8. Garancija in podpora

Warranty information for the DEVMO DC 5V/12V 1 Channel Relay Board is typically provided at the point of purchase or can be found on the manufacturer's official webZa posebne garancijske pogoje glejte dokumentacijo o nakupu.

For technical support, troubleshooting assistance, or further inquiries, please contact your retailer or the DEVMO customer service department through their official channels. Ensure you have your product model number (JZ801) and purchase details available when seeking support.

Ask a question about this manual