Eastman 70600
Eastman Nevercold Hot Water Recirculation Pump Kit
Model: 70600
Uvod
The Eastman Nevercold Hot Water Recirculation Pump Kit is designed to provide instant hot water throughout your home, reducing water waste and wait times. This system is specifically engineered for use with standard hot water heater tanks in single-pipe plumbing systems.
Important Note: This kit is not compatible with tankless water heaters and requires an electrical outlet for operation.
Konec izdelkaview in komponente
The Nevercold recirculating pump kit includes all necessary components for installation and operation:
- Stainless Recirculating Pump: Features a 3/4 inch FNPT union and an integrated built-in timer.
- Napajalni kabel: A 10-foot power cord for connecting the pump to an electrical outlet.
- Bronze Aqua Flash Bypass Valve: Includes a check valve for efficient water flow.
- Braided Water Supply Line: A 12-inch braided line for connection.
- Majica: For plumbing connections.

Image: All components of the Eastman Nevercold Hot Water Recirculation Pump Kit, including the pump, Aqua Flash valve, braided supply line, and tee.

Image: The Eastman Nevercold Universal Hot Water Recirculation Pump Kit, highlighting its purpose to provide hot water when needed.

Image: Visual representation of the system's easy installation and cost-saving benefits, including water and energy savings.
Nastavitev in namestitev
The circulating pump is designed for straightforward installation, typically completed within 30 minutes. It is ideal for homes with standard single-pipe plumbing systems up to 250 feet in length.
Koraki namestitve (splošna navodila):
- Priprava: Ensure the water heater is turned off and the water supply to the house is shut off. Drain hot water lines to relieve pressure.
- Namestitev črpalke: Install the stainless recirculating pump directly on your hot water heater tank's hot outlet.
- Namestitev obvodnega ventila: Install the bronze Aqua Flash bypass valve with check valve at the fixture furthest from the water heater (e.g., under a sink).
- Povezave: Use the provided 12-inch braided water supply line and tee to make the necessary plumbing connections between the hot and cold water lines at the bypass valve location.
- Električna povezava: Connect the 10-foot power cord to the pump and plug it into a standard electrical outlet.
- Aktivacija sistema: Restore water supply and power to the water heater. Check for leaks.
Caution: Always consult a qualified plumber if you are unsure about any installation steps. Ensure all connections are secure to prevent leaks.

Image: A schematic diagram illustrating how the Nevercold Circulator with built-in timer and the Nevercold Valve, Tee & Hose integrate into a typical tank system plumbing setup.
Video: Prekoračitevview of the Eastman Nevercold Recirculation Pump Kit, demonstrating its components and basic function. This video is a short preview.
Video: A detailed demonstration of the Eastman Nevercold Recirculation Pump Kit, showcasinnjegove lastnosti in prednosti.
Navodila za uporabo
The Eastman Nevercold pump features an integrated built-in timer. This timer allows you to program the pump to activate only during specific periods when hot water is typically needed, optimizing energy efficiency and hot water availability.
Nastavitev časovnika:
Refer to the timer dial on the pump unit. The dial typically has segments representing hours of the day. Push in the pins corresponding to the times you want the pump to operate. Ensure the current time is set correctly on the dial.

Slika: Bližnji posnetek view of the pump unit, clearly showing the integrated timer dial for scheduling operation.
When the pump is active, it circulates hot water from your water heater through the hot water lines and back, ensuring hot water is readily available at your faucets without significant delay.
Vzdrževanje
The Eastman Nevercold Recirculation Pump Kit is designed for low maintenance. Regular checks can help ensure optimal performance and longevity:
- Pregled puščanja: Periodically inspect all connections for any signs of leaks. Address any leaks promptly to prevent water damage and maintain system efficiency.
- Preverjanje časovnika: Verify that the timer settings are still appropriate for your hot water usage patterns. Adjust as needed.
- Čistost sistema: Keep the area around the pump and valve clean and free from debris.
- Prekinitev napajanja: If the water supply is turned off for any reason, it is recommended to unplug the pump unit to prevent it from running dry, which could cause damage.
Odpravljanje težav
| Težava | Možen vzrok | rešitev |
|---|---|---|
| Pump not running or no hot water circulation. |
|
|
| Cold water line gets hot. |
|
|
| Reduced hot water flow or long wait times. |
|
|
| Puščanje na priključkih. |
|
|
If you encounter issues not listed here or if the suggested solutions do not resolve the problem, please contact Eastman customer support for further assistance.
Specifikacije
| Atribut | Podrobnost |
|---|---|
| Znamka | Eastman |
| Številka modela | 70600 |
| Slog | Hot Water Heater Recirculation Pump Kit |
| Material | Medenina |
| barva | Črna |
| Dimenzije izdelka | 7.5 cm D x 10 cm Š x 7.5 cm V |
| Teža predmeta | 2 funta |
| Vir napajanja | Električni na kabel |
| voltage | 115 volta |
| Največja višina dviga | 250 Feet (for plumbing systems) |
| Proizvajalec | EZ-FLO |
| UPC | 091712027850 |
| Prvič na voljo | 1. december 2020 |
Informacije o garanciji
The Eastman Nevercold Hot Water Recirculation Pump Kit comes with a 3-year limited warranty on the pump. For specific terms and conditions, please refer to the warranty documentation included with your product or contact Eastman customer support.
Izbirni načrti zaščite:
Additional protection plans may be available for purchase to extend coverage beyond the manufacturer's warranty. These plans are typically offered by third-party providers.
- 3-letni načrt zaščite: Na voljo za podaljšano kritje.
- 4-letni načrt zaščite: Na voljo za podaljšano kritje.
- Popolna zaščita: A monthly plan that may cover eligible past and future purchases.
Note: These protection plans are separate from the manufacturer's warranty and are subject to their own terms and conditions.
Podpora uporabnikom
For technical assistance, warranty claims, or general inquiries regarding your Eastman Nevercold Hot Water Recirculation Pump Kit, please contact Eastman customer support. It is recommended to have your product model number (70600) and purchase date available when contacting support.
You can find contact information on the official Eastman webspletnem mestu ali v embalaži izdelka.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.