1. Uvod
The Wilo HiControl 1 is an electronic flow and pressure sensor designed for automatic control of pumps. It starts the pump when water is drawn and stops it when the flow ceases, providing constant pressure in domestic water supply systems. This device protects the pump from dry running and ensures efficient operation. Please read this manual carefully before installation and operation to ensure safe and correct use.
2. Varnostne informacije
Splošna varnost:
- Only qualified personnel should install and maintain this device.
- Disconnect power before performing any work on the device or pump.
- Zagotovite, da so vse električne povezave skladne z lokalnimi predpisi in standardi.
- Naprave ne uporabljajte, če je poškodovana.
- Protect the device from frost and direct sunlight.
Električna varnost:
- The device operates on 230 Volt AC/DC. Ensure the power supply matches the device's requirements.
- Pravilna ozemljitev je bistvena za preprečitev električnega udara.
- Naprave ne potapljajte v vodo.
3. Vsebina paketa
Po razpakiranju preverite, ali so vse komponente prisotne in nepoškodovane:
- Wilo HiControl 1 Pump Controller (Model 4190896)
- Navodila za uporabo
4. Izdelek je končanview
The Wilo HiControl 1 is a compact unit designed for easy integration into existing pump systems. It features a robust housing and clear indicators for operational status.

Figure 1: Wilo HiControl 1 Cold Water Pump Controller. This image shows the compact black unit with visible inlet and outlet connections, and a power cable connection point.
Ključne značilnosti:
- Automatic pump control based on flow and pressure.
- Integrated dry-running protection.
- Kompaktna zasnova za namestitev, ki prihrani prostor.
- Suitable for various cold water pump applications.
5. Nastavitev
Proper installation is crucial for the optimal performance and longevity of the Wilo HiControl 1.
5.1 Mehanska namestitev
- Mount the HiControl 1 vertically in the discharge line of the pump, ensuring the flow direction arrow on the device matches the water flow.
- Ensure the device is installed in a frost-free location and protected from direct weather exposure.
- Za preprečevanje puščanja uporabite ustrezne tesnilne materiale (npr. PTFE trak) na navojnih priključkih.
- Ensure there are no air pockets in the system after installation. Bleed the system thoroughly.
5.2 Električna povezava
- Connect the pump's power cable to the designated terminals on the HiControl 1. Refer to the wiring diagram inside the terminal box cover.
- Connect the main power supply (230V AC/DC) to the input terminals of the HiControl 1.
- Prepričajte se, da so vse povezave varne in ustrezno izolirane.
- Verify that the power supply is protected by a suitable circuit breaker and residual current device (RCD).
6. Navodila za uporabo
The Wilo HiControl 1 operates automatically once properly installed and powered.
6.1 Prvi zagon
- Ensure the pump and the entire hydraulic system are filled with water and free of air.
- Switch on the main power supply to the HiControl 1.
- The pump will start automatically and run for a few seconds to pressurize the system.
- Open a tap to draw water. The pump should start.
- Close the tap. The pump should continue to run for a short period (run-on time) and then stop.
6.2 Običajno delovanje
- When a tap is opened and water is drawn, the HiControl 1 detects the flow and starts the pump.
- When the tap is closed and the flow stops, the HiControl 1 detects the cessation of flow and stops the pump after a short delay.
- The integrated dry-running protection will stop the pump if no water is detected, preventing damage.
7. Vzdrževanje
The Wilo HiControl 1 requires minimal maintenance. Regular checks can help ensure reliable operation.
- Vizualni pregled: Periodically check the device for any signs of damage, leaks, or corrosion.
- Električne povezave: Prepričajte se, da so vse električne povezave tesne in brez korozije.
- Čiščenje: Očistite zunanjost naprave z oglasomamp krpo. Ne uporabljajte abrazivnih čistil ali topil.
- Zaščita proti zmrzovanju: In cold climates, ensure the device and associated piping are protected from freezing.
8. Odpravljanje težav
This section provides solutions to common issues you might encounter with the Wilo HiControl 1.
| Težava | Možen vzrok | rešitev |
|---|---|---|
| Pump does not start when tap is opened. | Brez napajanja. No water in the system (dry running protection activated). Blocked inlet/outlet. | Preverite napajalni priključek in odklopnik. Bleed the pump and system, ensure water supply. Check for obstructions in pipes. |
| Črpalka deluje neprekinjeno. | Puščanje v sistemu. Tap not fully closed. Okvara senzorja. | Check all pipes and connections for leaks. Ensure all taps are completely closed. Obrnite se na usposobljeno servisno osebje. |
| Pump starts and stops frequently (short cycling). | Small leak in the system. Zrak v sistemu. | Check for minor leaks. Bleed the system thoroughly to remove air. |
9. Specifikacije
| Funkcija | Specifikacija |
|---|---|
| Proizvajalec | WILO |
| Številka modela | 4190896 (HiControl 1) |
| Dimenzije izdelka | 7.7 x 9.3 x 6 cm |
| Teža | 1 kg |
| voltage | 230 volt |
| Vir energije | AC/DC |
| barva | Črna |
10. Garancija in podpora
Wilo products are manufactured to high-quality standards. For warranty information, please refer to the documentation provided with your purchase or visit the official Wilo website. For technical support, spare parts, or service, please contact your local Wilo dealer or authorized service center. When contacting support, please have your product model number (4190896) and serial number ready.