Secukey SK4-W

Secukey SK4-W Standalone Access Control System

Uporabniški priročnik

1. Uvod

This user manual provides comprehensive instructions for the installation, operation, and maintenance of the Secukey SK4-W Standalone Access Control System. Please read this manual carefully before installation and use to ensure proper functionality and safety.

The Secukey SK4-W is a robust, IP66-rated access control device designed for outdoor use, featuring RFID card and PIN code access. It is an ideal solution for securing doors, gates, and other entry points.

2. Izdelek je končanview

2.1 Ključne lastnosti

  • IP66 Waterproof and Anti-Vandal Design: Suitable for harsh outdoor environments.
  • Načini večkratnega dostopa: Supports RFID card only, PIN code only, or Card + PIN for enhanced security.
  • Visoka uporabniška zmogljivost: Manages up to 1000 users.
  • Integrirani rele: Built-in NO, NC, Com relay for direct door lock control.
  • Adjustable Output Times: Programmable lock output time (1-99 seconds) and alarm output time (1-3 minutes).
  • Wiegand 26-bit Interface: Supports external Wiegand readers, exit buttons, and alarms.
  • Latch Mode: Allows the door or gate to remain open.
  • Wide Voltage Domet: Operates on 12~28V AC/DC.
  • Osvetljena tipkovnica: Zagotavlja vidljivost v slabih svetlobnih pogojih.
  • Vzdržljiva konstrukcija: Zinc alloy casing with powder coating.

2.2 Vključene komponente

  • 1 x Secukey SK4-W Standalone Access Control Device (RFID/PIN)
  • 1 x Master Add Card
  • 1 x Master Delete Card
  • 1 x uporabniški priročnik

2.3 Izdelek Views

Spredaj view of the Secukey SK4-W access control system, showing the silver casing and black keypad with numbers 0-9, asterisk, and hash symbols.

Slika 1: Spredaj view of the SK4-W unit, highlighting the keypad and Secukey branding.

Nagnjena sprednja stran view of the Secukey SK4-W access control system, showing the silver casing and black keypad.

Slika 2: Pod kotom view of the SK4-W, providing a perspective of its slim profile.

Stran view of the Secukey SK4-W access control system, emphasizing its compact design.

Slika 3: stran view of the SK4-W unit.

Druga stran view of the Secukey SK4-W access control system, showing the depth of the unit.

Slika 4: Druga stran view of the SK4-W unit.

Nazaj view of the Secukey SK4-W access control system, showing the wiring harness for connections.

Slika 5: Zadaj view of the SK4-W unit, displaying the integrated wiring for installation.

3. Nastavitev in namestitev

3.1 Namestitev naprave

The SK4-W is designed for surface mounting. Choose a secure location near the door or gate, ensuring it is within reach for users and protected from direct impact. Use appropriate screws and wall plugs for the mounting surface.

3.2 Shema ožičenja

The device requires a 12~28V AC/DC power supply (not included). Connect the wires according to the diagram provided in the full manual. Ensure all connections are secure and insulated to prevent short circuits.

  • Vhodna moč: Connect to 12~28V AC/DC power source.
  • Lock Output (NO/NC/COM): Connect to your electric lock.
  • Izhod alarma: Connect to an external alarm system (if applicable).
  • Wiegand In/Out: For connecting external Wiegand readers or other Wiegand devices.
  • Gumb za izhod: Connect a push-to-exit button for convenient egress.

For detailed wiring schematics, please refer to the comprehensive wiring diagram included in the product packaging.

4. Navodila za uporabo

4.1 Initial Setup and Master Cards

Upon first power-up, the device will be in factory default mode. Use the included Master Add Card and Master Delete Card to manage user access.

  • Dodajanje uporabnikov: Present the Master Add Card, then present the new user's RFID card or enter their PIN.
  • Brisanje uporabnikov: Present the Master Delete Card, then present the user's RFID card or enter their PIN to be deleted.

4.2 Načini dostopa

The SK4-W supports three primary access modes:

  1. Card Only Mode: Users gain access by presenting a valid RFID card.
  2. PIN Only Mode: Users gain access by entering a valid 4-6 digit PIN code.
  3. Card + PIN Mode: Users must present a valid RFID card and then enter their corresponding PIN code for access. This mode offers the highest security.

Refer to the full programming guide for instructions on how to switch between access modes and manage user PINs.

4.3 Visitor PINs

The SK4-W supports up to 10 visitor PINs, which can be set to be valid for 1 to 10 uses. This feature is useful for temporary access for guests or service personnel.

Image illustrating the visitor PIN feature, showing a person using the access control system and a separate image of the device in water, indicating IP66 waterproof rating.

Figure 6: The SK4-W supports visitor PINs and is IP66 waterproof, suitable for outdoor installation.

4.4 Latch Mode

The latch mode allows the door or gate to remain unlocked for an extended period, which can be useful during peak hours or for maintenance. Consult the programming manual for activation and deactivation procedures.

5. Vzdrževanje

The Secukey SK4-W is designed for minimal maintenance due to its robust construction and IP66 rating. However, regular checks can prolong its lifespan and ensure optimal performance.

  • Čiščenje: Wipe the keypad and casing z mehkim, damp krpo. Izogibajte se abrazivnim čistilom ali topilom.
  • Preverjanje povezave: Periodically inspect wiring connections for any signs of wear, corrosion, or loosening.
  • Posodobitve vdelane programske opreme: Preverite pri proizvajalcu webza morebitne razpoložljive posodobitve vdelane programske opreme.
Image showing the Secukey SK4-W access control system embedded in ice, illustrating its ability to operate in extreme cold temperatures down to -40 degrees Celsius.

Figure 7: The SK4-W is designed to withstand extreme operating temperatures, from -40°C to 60°C.

6. Odpravljanje težav

TežavaMožen vzrokrešitev
Naprava se ne vklopi.Ni napajanja; napačna glasnosttage; loose wiring.Check power connections and ensure correct 12~28V AC/DC supply. Verify wiring.
RFID kartica ni prepoznana.Card not enrolled; incorrect card type (not 125 KHz EM); damaged card.Ensure the card is properly enrolled. Verify it is a 125 KHz EM card. Try another card.
PIN koda ne deluje.Incorrect PIN; PIN not enrolled; device in card-only mode.Double-check the PIN. Ensure the PIN is enrolled. Verify the access mode setting.
Ključavnica vrat se ne aktivira.Incorrect lock wiring (NO/NC); lock power issue; relay output time too short.Check lock wiring and power. Adjust the lock output time in settings.
Wiegand output issues.Incorrect Wiegand wiring; incompatible Wiegand device.Verify Wiegand 26-bit wiring. Ensure external device compatibility.

If the problem persists, please contact Secukey technical support for assistance.

Diagram illustrating Wiegand 26-bit input and output data signals, showing Data 0 and Data 1 waveforms with timing specifications.

Figure 8: Wiegand 26-bit input and output signal timing diagram.

7. Specifikacije

AtributVrednost
Številka modelaSK4-W
ZnamkaSecukey
Dimenzije (D x Š x V)13.0 x 5.6 x 2.3 cm
Teža500 gramov
barvaSrebrna
Napajalnik12 ~ 28V AC / DC
Ocena zaščite pred vdorom (IP).IP66 (Waterproof, Anti-Vandal)
Uporabniška zmogljivostDo 1000 uporabnikov
Dolžina kode PIN4 do 6 števk
Vrsta kartice125 KHz EM Card
Wiegandov vmesnikWiegand 26-bit Input & Output
Zakleni izhodno obremenitev3 A maks
Izhodna obremenitev alarma3 A maks
Delovna temperatura-40 °C do 60 °C (-40 F do 140 F)
Delovna vlažnost10 % do 90 % (brez kondenzacije)
Casing MaterialZinc Alloy with Powder Coating

8. Garancija in podpora

Secukey products are manufactured to high quality standards. For warranty information and technical support, please refer to the warranty card included with your product or visit the official Secukey webmesto.

Kontaktni podatki:

  • Proizvajalec: Secukey
  • Webspletno mesto: www.secukey.com (Npramppovezava, dejanska povezava se lahko razlikuje)
  • Storitev za stranke: Glejte embalažo izdelka ali webspletno mesto za regionalne stike s podporo.

Za garancijske zahtevke shranite dokazilo o nakupu.

© 2024 Secukey. All rights reserved. Information subject to change without notice.

Ask a question about this manual