1. Uvod
Thank you for choosing the ABUS 3632 Door Closer TS40 AL. This spring-loaded automatic door closer is designed for flush doors, providing reliable and controlled closing. It features three adjustable closing force levels to suit various door weights and closing requirements. This manual provides essential information for safe installation, operation, and maintenance of your door closer.
2. Varnostne informacije
- Pred namestitvijo in uporabo natančno preberite vsa navodila.
- Ensure all fixing materials are securely fastened to prevent injury or damage.
- Do not attempt to disassemble or modify the door closer. This may void the warranty and pose a safety risk.
- Med delovanjem in nastavljanjem držite roke in prste stran od gibljivih delov.
- This door closer is intended for a maximum door weight of up to 20 kg. Exceeding this limit may result in improper function or damage.
- Always use appropriate tools for installation.
3. Vsebina paketa
The ABUS 3632 Door Closer TS40 AL package includes:
- 1 x ABUS Door Closer TS40 AL unit
- All necessary fixing materials (screws, etc.)
- Navodila za uporabo (ta dokument)
4. Specifikacije izdelka
| Številka modela: | 3632 |
| Material: | Alloy Steel, Aluminium |
| barva: | Srebrna |
| Zunanja obdelava: | Srebrna |
| Mere izdelka (D x Š x V): | 340 mm x 95 mm x 27 mm (13.39" x 3.74" x 1.06") |
| Teža artikla: | 0.34 kg |
| Vrsta namestitve: | Privijanje |
| Priporočena uporaba: | Commercial, Flush Doors |
| maks. Teža vrat: | Do 20 kg |
| Closing Force Levels: | 3 nastavljive ravni |
| Združljivost: | DIN right / DIN left doors |
Figure 1: Technical dimensions of the ABUS 3632 Door Closer. The main body is 180mm long, and the arm is 163mm long.
5. Nastavitev in namestitev
The ABUS 3632 Door Closer TS40 AL is designed for easy screw-in installation on flush doors. It is compatible with both DIN right and DIN left opening doors.
5.1 Pred namestitvijo
- Ensure the door is clean and free from obstructions.
- Verify that the door weight does not exceed 20 kg.
- Gather necessary tools: drill, screwdriver, measuring tape, pencil.
5.2 koraki namestitve
- Positioning the Closer: Determine the desired mounting position on the door frame or door leaf. The closer can be mounted on the pull side or push side, depending on the door's opening direction (DIN right/left).
- Označevanje izvrtin: Use the door closer as a template to mark the screw hole positions on the door or frame. Ensure the closer is level.
- Vrtanje pilotnih lukenj: Drill pilot holes at the marked positions. The size of the drill bit should be slightly smaller than the screws provided.
- Attaching the Closer Body: Securely fasten the main body of the door closer to the door or frame using the provided screws.
- Attaching the Arm: Attach the arm to the door closer body and to the door frame or door leaf, depending on the mounting configuration. Ensure all connections are tight.
- Začetni test: Open and close the door a few times to ensure smooth operation and proper alignment.
Figure 2: Illustration of DIN right and DIN left door applications.
Figure 3: ABUS 3632 Door Closer TS40 AL correctly installed on a door.
6. Delovanje in nastavitev
The ABUS 3632 Door Closer TS40 AL features a smooth, 3-stage closing strength adjustment. This allows you to fine-tune the closing speed and force to match your specific needs and door characteristics.
6.1 Adjusting Closing Force
The closing force is adjusted via a screw mechanism located on the main body of the door closer. Refer to the diagram below for the exact location.
- To Increase Closing Force: Turn the adjustment screw clockwise.
- To Decrease Closing Force: Turn the adjustment screw counter-clockwise.
Test the door's closing action after each adjustment to achieve the desired speed and force. Avoid over-tightening or loosening the screw excessively.
Figure 4: Detail of the ABUS 3632 Door Closer, showing the adjustment point.
7. Vzdrževanje
Regular maintenance ensures the longevity and optimal performance of your ABUS door closer.
- Čiščenje: Wipe the door closer periodically with a soft, damp krpo, da odstranite prah in umazanijo. Izogibajte se abrazivnim čistilom ali topilom.
- Mazanje: The internal mechanism is factory-lubricated and generally does not require additional lubrication. If squeaking or stiffness occurs, consult a professional.
- Preverjanje pritrdilnih elementov: Periodically check all mounting screws and fasteners to ensure they are tight. Re-tighten if necessary to prevent loosening over time.
- Preverjanje funkcionalnosti: Regularly test the door closer's operation to ensure the door closes smoothly and at the desired speed. Adjust the closing force if needed.
8. Odpravljanje težav
| Težava | Možen vzrok | rešitev |
|---|---|---|
| Vrata se ne zaprejo popolnoma. | Closing force is too low. Obstruction in door path. | Increase closing force (refer to Section 6.1). Check for and remove any obstructions. |
| Door closes too quickly/slams. | Closing force is too high. | Decrease closing force (refer to Section 6.1). |
| Zapiralo vrat je hrupno. | Loose fasteners. Internal mechanism issue. | Check and tighten all mounting screws. If noise persists, contact ABUS support. |
| Door closer feels stiff or inconsistent. | Lack of lubrication (rare). Damage to internal components. | Ensure no external debris is affecting movement. If issues persist, contact ABUS support. |
9. Garancija in podpora
ABUS products are manufactured to high-quality standards. For specific warranty information, please refer to the warranty card included with your purchase or visit the official ABUS website. If you encounter any issues not covered in this manual or require further assistance, please contact ABUS customer support.
Uradnik ABUS-a Webspletno mesto: www.abus.com