BUFFALO LSW3-GT-24NSR

BUFFALO Giga Switching Hub 24-Port LSW3-GT-24NSR User Manual

1. Uvod

The BUFFALO Giga Switching Hub LSW3-GT-24NSR is a 24-port Gigabit Ethernet switch designed for high-speed network environments. It is ideal for small to medium-sized offices and workplaces requiring robust and reliable network connectivity. This device supports full Gigabit speeds across all ports, ensuring efficient data transfer.

Key features include a fanless design for silent operation and enhanced reliability, as well as a loop detection function to prevent network disruptions caused by accidental network loops.

2. Varnostne informacije

Please read and understand the following safety precautions before using the device to prevent injury or damage.

  • Napajanje: Use only the provided power adapter. Ensure the power outlet meets the specified voltage zahteve.
  • Prezračevanje: Ne blokirajte prezračevalnih odprtin. Zagotovite zadosten pretok zraka okoli naprave, da preprečite pregrevanje.
  • Okolje: Avoid exposing the device to water, high humidity, extreme temperatures, or direct sunlight.
  • Ravnanje: Do not drop or subject the device to strong impacts. Do not attempt to open or repair the device yourself. Refer all servicing to qualified personnel.
  • Kabli: Ensure all network cables are properly connected and secured.

3. Vsebina paketa

Preverite, ali so v paketu prisotni vsi elementi:

  • BUFFALO Giga Switching Hub LSW3-GT-24NSR Unit
  • Napajalni kabel
  • Rack Mount Brackets (if included with your model)
  • Gumijaste nogice (za postavitev na mizo)

4. Nastavitev

4.1 Fizična namestitev

The LSW3-GT-24NSR can be installed on a desktop or mounted in a 19-inch equipment rack.

Postavitev na namizje:

  1. Attach the included rubber feet to the bottom of the unit to prevent slipping and provide stability.
  2. Place the unit on a flat, stable surface with adequate ventilation.

Montaža na stojalo:

  1. Attach the rack mount brackets to the sides of the unit using the provided screws.
  2. Secure the unit into a standard 19-inch equipment rack using appropriate rack screws (not included).

4.2 Priključitev omrežnih kablov

Connect your network devices (computers, servers, other switches) to any of the 24 RJ-45 ports on the front panel using standard Ethernet cables (Category 5e or higher recommended for Gigabit speeds).

Spredaj view of the BUFFALO LSW3-GT-24NSR Giga Switching Hub, showing 24 Ethernet ports and LED indicators.

Slika 1: Sprednja plošča zgorajview with 24 Ethernet Ports and Status LEDs.

4.3 Priključitev napajanja

  1. Connect the power cable to the AC IN port on the rear of the device.
  2. Drugi konec napajalnega kabla priključite v ustrezno vtičnico.
  3. The device will power on automatically. The POWER LED on the front panel should illuminate.
Zadaj view of the BUFFALO LSW3-GT-24NSR Giga Switching Hub, showing the AC IN power port.

Slika 2: Zadnja ploščaview with AC IN Power Port.

5. Navodila za uporabo

5.1 LED indikatorji

The front panel features several LED indicators to monitor the status of the switch and its ports.

Od blizu view of the LED indicators and Loop Detection switch on the BUFFALO LSW3-GT-24NSR.

Slika 3: Podrobno view of LED Indicators and Loop Detection Switch.

Tabela 1: Stanje LED indikatorja
Ime LEDStanjeOpis
MOČOnNaprava je vklopljena.
POVEZAVA / AKT (na vrata)OnA network device is connected and a link is established.
UtripaPodatki se prenašajo ali prejemajo prek vrat.
1000/100/10M (na vrata)zelenaPort is operating at 1000 Mbps (Gigabit Ethernet).
OranžnaPort is operating at 100 Mbps (Fast Ethernet).
IzključenoPort is operating at 10 Mbps (Ethernet).
LOOP DETECTOnA network loop has been detected.

5.2 Funkcija zaznavanja zanke

The LSW3-GT-24NSR features a hardware switch for enabling or disabling the loop detection function. This function helps prevent network instability caused by accidental network loops.

Od blizu view of the Loop Detection switch on the BUFFALO LSW3-GT-24NSR, showing ON and OFF positions.

Figure 4: Loop Detection Switch (ON/OFF).

  • VKLOPLJENO: Loop detection is active. If a loop is detected, the corresponding port will be automatically shut down to prevent network broadcast storms, and the LOOP DETECT LED will illuminate.
  • IZKLOPLJENO: Loop detection is disabled.

It is recommended to keep the loop detection function ON for network stability.

6. Vzdrževanje

6.1 Čiščenje naprave

To maintain optimal performance, periodically clean the exterior of the switch.

  • Pred čiščenjem izključite napajalni kabel.
  • Za brisanje površine uporabite mehko, suho krpo.
  • Do not use liquid cleaners, aerosols, or solvents, as these may damage the casing ali notranjih komponent.

6.2 Okoljski vidiki

Ensure the device is operated within its specified environmental conditions:

  • Temperatura: 0 °C do 40 °C (32 °F do 104 °F)
  • Vlažnost: 10 % do 85 % (brez kondenzacije)

7. Odpravljanje težav

If you encounter issues with your BUFFALO Giga Switching Hub, refer to the following common problems and solutions.

7.1 Brez napajanja

  • Simptom: LED POWER ne sveti.
  • rešitev: Check if the power cable is securely connected to both the device and the power outlet. Ensure the power outlet is functional.

7.2 No Link or Slow Speed on a Port

  • Simptom: The LINK/ACT LED for a connected port is off, or the 1000/100/10M LED indicates a lower speed than expected (e.g., 100M instead of 1000M).
  • rešitev:
    • Preverite, ali je ethernetni kabel varno priključen na obeh koncih.
    • Try a different Ethernet cable. Ensure it is a Category 5e or higher cable for Gigabit speeds.
    • Napravo priključite na druga vrata na stikalu.
    • Check the network adapter settings on the connected device (computer, server) to ensure it is configured for auto-negotiation or the correct speed.

7.3 Network Instability / LOOP DETECT LED is On

  • Simptom: The LOOP DETECT LED is illuminated, and network performance is degraded or unstable.
  • rešitev:
    • A network loop has been detected. This typically occurs when two ports on the same switch (or different switches) are connected to each other, creating an infinite data path.
    • Carefully inspect your network cabling to identify and remove any redundant connections that form a loop.
    • If the loop detection switch is ON, the affected port will be automatically shut down. Once the loop is resolved, the port should resume normal operation.

8. Specifikacije

Tabela 2: Specifikacije izdelka
FunkcijaOpis
ZnamkaBIVOLI
Številka modelaLSW3-GT-24NSR
Število vrat24 x 10/100/1000BASE-T RJ-45 vrat
Preklopna zmogljivost48 Gbps (Non-blocking)
Stopnja posredovanja35.7 Mpps
Velikost tabele naslovov MAC8K vnosov
Podpora za okvir JumboDo 9 KB
LastnostiAuto-MDI/MDIX, Auto-Negotiation, Loop Detection Function, Fanless Design
NapajalnikNotranji AC napajalnik
Dimenzije (Š x G x V)(Specific dimensions not provided in source, typical for 1U rackmount)
Teža(Specific weight not provided in source)
Delovna temperatura0°C do 40°C
Delovna vlažnost10 % do 85 % (brez kondenzacije)

9. Garancija in podpora

This BUFFALO product is covered by a manufacturer's warranty. Please refer to the warranty card included with your product or visit the official BUFFALO webza podrobne garancijske pogoje.

For technical support, product registration, or further assistance, please visit the official BUFFALO support webspletno mesto ali se obrnite na njihov oddelek za pomoč strankam. Kontaktne podatke običajno najdete na proizvajalčevi strani webmestu ali v embalaži izdelka.